Lock Relay Connection 

 

Device Not Sharing Power with the Lock 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1 

+12V 

GND 

GND  Sensor 

NC1 

FR107 
Diode 

12V DC Adaptor 

Normally Closed Lock 

Notes: 

1.

 

The system supports 

NO LOCK

 and 

NC LOCK

. For example the 

NO 

LOCK

 (normally opened at power on) is connected with '

NO1

' and 

'

COM1

' terminals, and the 

NC LOCK

 (normally closed at power on) is 

connected with '

NC1

'and '

COM1

' terminals. 

2.

 

When electrical lock is connected to the Access Control System, you 
must parallel one FR107 diode (equipped in the package) to prevent 
the self-inductance EMF from affecting the system. 

Do not reverse the polarities. 

Summary of Contents for ProCapture-WP

Page 1: ...QUICK START GUIDE Applicable Models ProCapture WP Version 1 0 Date July 2017...

Page 2: ...damage the device Do not place the device next to heating equipment Do not to let liquid like water drinks or chemicals leak inside the device Do not let children touch the device without supervision...

Page 3: ...2 Device Overview 2 4 Inch Color Screen Touch Keypad Doorbell LED Indicator Fingerprint Sensor Card Reader Area Reset Button Front Left Side Back...

Page 4: ...186 5 mm 3 0 in 76 1 mm Fix the back plate onto the wall using wall mounting screws Note We recommend drilling the mounting plate screws into solid wood i e stud beam If a stud beam cannot be found us...

Page 5: ...onnection Without UPS With UPS Optional Recommended Power Supply 12V DC Adaptor GND 12V 12V DC Adaptor 12V 10 at least 500MA To share the power with other devices use a power supply with higher curren...

Page 6: ...5 Ethernet Connection LAN Connection Network Cable Adaptor Ethernet Cable Note The device can be connected to PC directly by Ethernet cable...

Page 7: ...fingerprint reader switches 1 4 are for RS485 address switch 5 is reserved switch 6 is for reducing noise on long RS485 cable 2 If RS485 fingerprint reader is powered from the terminal the length of w...

Page 8: ...r example the NO LOCK normally opened at power on is connected with NO1 and COM1 terminals and the NC LOCK normally closed at power on is connected with NC1 and COM1 terminals 2 When electrical lock i...

Page 9: ...8 Lock Relay Connection Device Sharing Power with the Lock COM1 12V GND Sensor NC1 FR107 Diode Normally Closed Lock GND...

Page 10: ...9 Wiegand Output Connection WD0 WD1 GND...

Page 11: ...10 Standalone Installation Ethernet Exit Button Doorbell Lock Door Sensor RS485 Fingerprint Reader...

Page 12: ...access control role Ethernet Settings Press to enter the main menu and press to select Comm Ethernet The Parameters below are the factory default values Please adjust them according to the actual netw...

Page 13: ...registered user must meet the following conditions 1 User s access time falls within either user s personal time zone or group time zone 2 User s group must be in the access combo when there are other...

Page 14: ...low on the finger and retry 2 Invalid time zone is displayed after verification Contact Administrator to check if the user has the privilege to gain access within that time zone 3 Verification succeed...

Page 15: ...rademark of ZKTeco or a related company All other product and company names mentioned are used for Identification purposes only and may be the trademarks of their respective owners All specifications...

Reviews: