background image

KF1000 Series

User Manual

P a g e

|

41

Copyright©2022 ZKTECO CO., LTD. All rights reserved.

5.3

Add Personnel on the Software

1.

Click

[Personnel] > [Person] > [New]

and fill in all the required fields to

register new users in the software.

Note:

The card number must be entered for use with the inBio series controllers.

2.

Click

[Access] > [Device] > [Device] > [Control] > [Synchronize All Data to

Devices]

to synchronize all the data to the device including the new users.

For more details, please refer to the ZKBioAccess IVS User Manual.

Summary of Contents for KF1000 Series

Page 1: ...ank you for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual ar...

Page 2: ...he property of ZKTeco The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco The contents of this manual must be read as a w...

Page 3: ...ined from using the information is assumed by the user ZKTeco in no event shall be liable to the user or any third party for any incidental consequential indirect special or exemplary damages includin...

Page 4: ...iii in case of operation of the machine and equipment in conditions different from the prescribed conditions of the manual The product will be updated from time to time without prior notice The lates...

Page 5: ...of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhan...

Page 6: ...and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description T...

Page 7: ...N 12 2 2 1 POWER WIRING 12 2 2 2 INBIO WIRING 13 2 2 3 DM10 WIRING 14 3 INSTALLATION SET UP 15 3 1 SAFETY PRECAUTIONS 15 3 2 INSTALLATION SITE 15 3 3 INSTALLATION STEPS 15 4 CONFIGURATION VIA WEBSERVE...

Page 8: ...4 4 5 SYSTEM SETTINGS 26 4 4 6 SERIAL COMM SETTINGS 26 4 4 7 FACE PARAMETERS 28 4 4 8 AUTOTEST 31 4 4 9 WIEGAND SETUP 31 4 5 DEVICE MANAGEMENT 35 4 5 1 DEVICE MANAGEMENT 35 4 5 2 UPDATE FIRMWARE 36 4...

Page 9: ...also available to communicate with InBio Controllers for authentication use The whole system is compiled with the ZKTeco Cyber Security Base Line ZKCSBL to ensure that users data is under the finest p...

Page 10: ...KF1000 Series User Manual P a g e 9 Copyright 2022 ZKTECO CO LTD All rights reserved 1 3Appearance...

Page 11: ...lash 4 LED Indicator 5 Receive Antenna Card Reading Area 6 Speaker 7 Tamper Switch 8 Restart Button 9 Reset Button 10 Mounting Hole 11 Wiring Hole Remark If you forget the WebServer password you can r...

Page 12: ...Description 2 1Terminal Description Figure 1 2 Terminal Description Table 1 2 Description of Terminal and Interfaces Name Interface Description Power GND 12V DC Input Note Minimum AC adapter 12V 1 5A...

Page 13: ...to DM10 OSDP Output Note User need to enable the DM10 OSDP Output function on the WebServer to access it 485B Ethernet LAN Network Interface 2 2Wiring Description 2 2 1 Power Wiring Figure 1 3 Power W...

Page 14: ...ller After the controller sends the data to the KF1000 series device the user can perform face verification on the device It is also possible to connect the reader with the input device and output dev...

Page 15: ...s via RS485 You need to manually enable the DM10 function on the Webserver to access it It can be turned on via the following path Advanced Settings Serial Comm Serial Port DM10 Set the 485 address of...

Page 16: ...not place the device on an unstable case or desk The device might be damaged severely in case of a fall Do not open the chassis when the attendance device is operating or when electrical hazards are...

Page 17: ...and connecting them to the device and then attach the device to the back plate from top to bottom Step 4 Fasten the device to the back plate with a security screw Figure1 5 KF1000 Series Installation...

Page 18: ...ress and server port in the address bar The IP address is set as https device IP address Port for example https 192 168 1 201 1443 Device IP address 192 168 1 201 is the default You can modify the add...

Page 19: ...password otherwise the webserver function will be locked 4 2System Information The System Information includes the device device capacity and firmware information 4 2 1 Device Information The Device...

Page 20: ...2 2 Device Capacity The Device Capacity displays the User Capacity Admin User Password the used max capacity of Face the used max capacity of Card and the used max capacity of T A Record 4 2 3 Firmwar...

Page 21: ...O LTD All rights reserved 4 3User Management You can manage the basic information of the registered users including User ID Name Rights CardNumber andVerificationModeintheUserManagement 4 3 1 Add User...

Page 22: ...to the prompt of the LED indicator of the device so that all the important features of the face can be captured by the camera Then stay still for a while during face registration until registration i...

Page 23: ...st and Wiegand Setup 4 4 1 Communication Settings When the device needs to communicate with a PC over the Ethernet you need to configure network settings and ensure that the device and the PC are conn...

Page 24: ...ting with the ADMS server Enable Domain Name When this function is enabled the domain name mode http is used such as http www XYZ com XYZ denotes the domain name When this mode is turned OFF you need...

Page 25: ...rts the Wi Fi module which is built in within the hardware to enable data transmission via Wi Fi and establish a wireless network environment By default the Wi Fi is turned off The user needs to enabl...

Page 26: ...htSavingMode Enable ordisable theDaylight SavingTimeMode by date time mode and by week day mode for selection Notes DST which is also called Daylight Saving Time is a system adjusting local time to sa...

Page 27: ...ackward at XX hour XX day XX month How to set the Daylight Saving Time For example adjust the clock forward one hour at 08 00 on April 1 and backward one hour at 08 00 on October 1 the system turns ba...

Page 28: ...municates with the OSDP Output through RS485 serial port DM10 Communicates with the DM10 through RS485 serial port Baudrate The rate of the communication with PC there are 5 options of baud rate 11520...

Page 29: ...lower the misjudgment rate and higher the rejection rate and vice versa The default value of 47 is recommended 1 1 Threshold Value Under 1 1 verification mode the verification will only be successful...

Page 30: ...ill be filtered by the algorithm i e ignored by the terminal thus no registration and comparison interface will be triggered Image Quality It is the image quality for facial registration and compariso...

Page 31: ...isible light images to determine if the provided biometric source sample is of a real person a live human being or a false representation Live Detection Threshold It facilitates judging whether the ca...

Page 32: ...r Manual P a g e 31 Copyright 2022 ZKTECO CO LTD All rights reserved 4 4 8 Autotest Test Face To test if the camera functions properly by checking the pictures taken to see if they are clear enough 4...

Page 33: ...parity bit of the 2nd to 13th bits while the 26th bit is the odd parity bit of the 14th to 25th bits The 2nd to 25th bits are the card numbers Wiegand26a ESSSSSSSSCCCCCCCCCCCCCCCCO It consists of 26...

Page 34: ...bits The 2nd to 17th bits are the device codes The 18th to 33rd bits are the card numbers and the 34th to 35th bits are the manufacturer codes Wiegand36a EFFFFFFFFFFFFFFFFFFCCCCCCCCCCCCCCCCO It consis...

Page 35: ...th to 20th bits are the site codes and the 21st to 36th bits are the card numbers Wiegand50 ESSSSSSSSSSSSSSSSCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCO It consists of 50 bits of binary code The 1st bit is the...

Page 36: ...the device 4 5 1 Device Management Clear Administrator To delete all the administrator Restart To restart the device Reset The Factory Reset function restores the device settings such as communicatio...

Page 37: ...oading to upload the upgrade file in emfw cfg format And then click Confirm to upgrade firmware Note Make sure the size of the upgrade file is less than 200M If an upgrade file is needed please contac...

Page 38: ...to change the password he can set it on the Change Password window The user can enter the current password in the Reset Password window andclick ResetPassword torestorethedeviceto thefactorypassword...

Page 39: ...erved 4 5 4 Operation Log After entering the start time and end time the user can view the Operation Logs on the page and click Download to download the operation logs 4 5 5 Download Firmware Logs Use...

Page 40: ...hts reserved 5 Connect to ZKBioAccess IVS Software 5 1Set the Communication Address Click Advanced Settings COMM IP Address to set the IP address and then click Advanced Settings Cloud Service Setup t...

Page 41: ...ice on the Software Add the device by searching The process is as follows 1 Click Access Device Device Search to search the device on the software When an appropriate server address and port is set on...

Page 42: ...w and fill in all the required fields to register new users in the software Note The card number must be entered for use with the inBio series controllers 2 Click Access Device Device Control Synchron...