4
2
System Introduction
The Access Control management system is a new modernized security management system, which
is an effective measure of security and protection management. It is mainly used to manage the
entrances and exits of highly secured places, such as banks, hotels, equipment rooms, offices, smart
communities, and factories.
System Functional Parameters
2.1
High-speed 32-bit 1.2GHz CPU, 128M RAM, and 256M Flash.
Embedded LINUX operating system.
One-door/two-door two-way access or four-door one-way access.
Fingerprint capacity: 20,000.
A maximum of 60,000 cardholders and 100,000 offline event records.
Support of multiple Wiegand card formats and a password keypad, compatible with various
types of cards.
Use Ethernet and RS485 industrial bus dual communication technology, for reliable
communications.
Control Panel with a watchdog (hardware) built in to prevent a crash.
Over-current, over-voltage, and inverse-voltage protection for the input of the power supply
to the control panel.
Over-current protection for the power supply to card readers.
Instant over-voltage protection for all input/output ports.
Instant over-voltage protection for communication ports.
Product Technical Parameters
2.2
Working Power supply: Rated voltage 12V (±20%) DC, rated current is 2A.
Working environment: Temperature 0°C to 45°C; Humidity 20% to 80%.
Electronic lock relay output: The maximum switching voltage is 12V(DC); The maximum
switching current is 2A.
Auxiliary relay output: The maximum switching voltage is 12V(DC); The maximum switching
current is 1.25A.
The detachable connection terminals are made of alloy-steel non-magnetic flange materials.
Summary of Contents for InBio160
Page 1: ...USER MANUAL Applicable Models InBio160 260 460 Pro Access Control Panel Version 1 0 ...
Page 10: ...6 Indicator Diagram Figure 2 1 Indicators in the InBio460 Pro ...
Page 13: ...9 Control Panel System Installation 3 3 Figure 3 2 Schematic Diagram of System Installation ...