8
Installation of Access Control Panel Wires
3.2
Figure 3-1 Access Control Panel Wire Installation Diagram
Remarks:
Ensure the power supply is disconnected before connecting the wires; otherwise, it may
cause severe damage to the equipment.
The access control wires must be separated according to heavy and light current; the control
panel wires, electronic lock wires, and exit button wires must run through their casing pipes,
respectively.
Control Panel
Door sensor
Electronic lock
Exit button
Indoor wiegand card reader
Outdoor
wiegand
card reader
Ceiling
Outdoor
TCP/IP Network communication wire
Indoor
+12V Power line
RS485 Network communication wire