28
Restoring factory setting
The silk-screened
7
(place 7) of the DIP switch is the switch for restoration of system settings. The
place is set to
OFF
by default. When place 7 is moved upwards and downwards for three times
within 10 seconds and finally returned to the
OFF
position, the factory settings will be restored after
the access control operator panel is restarted.
Terminal resistance setting
Place 8 is for setting the RS485 termination resistance. Putting the switch to the
ON
position is
equivalent to parallel connection of a 120ohm termination resistance between 485+ and 485-.
ZKPanelWeb
4.5
To help users conveniently manage controllers, the built-in Web Server function is added to some
models. With this function, a user can connect to the controller through a PC, and enter the IP
address of the controller to access the web. Users can also use the Web Server function to perform
other operations, such as network configuration, Push communication configuration, time
synchronization, and user account management.
Log on to the Web Server
1.
Connect the controller to the network or PC, start the browser, enter the IP address of the
controller, which is
by default. Then you can visit the Web Server.
2.
When Web Server is used, “User Name“ and “Password“ should be set firstly. The default “user
name” is
admin
and the default “password” is
zkteco@12345
.
Summary of Contents for InBio160
Page 1: ...USER MANUAL Applicable Models InBio160 260 460 Pro Access Control Panel Version 1 0 ...
Page 10: ...6 Indicator Diagram Figure 2 1 Indicators in the InBio460 Pro ...
Page 13: ...9 Control Panel System Installation 3 3 Figure 3 2 Schematic Diagram of System Installation ...
Page 15: ...11 InBio260 Pro Terminal connection diagram ...