Wiegand output 

 

Item 

Descriptions 

SRB 

When SRB is enabled, the lock is controlled by the SRB  to prevent the lock 
from being opened due to device removal. 

Wiegand Format 

Values range from 26 bits, 34 bits, 36 bits, 37 bits, and 50 bits. 

Wiegand output bits 

After choosing the Wiegand  format, you can select one of the corresponding 
output digits in the Wiegand format 

Failed ID 

If the verification is failed, the system will send the failed ID to the device and 
replace the card number or personnel ID with the new ones.  

Site Code 

It is similar to the device ID. The difference is that a site code can be set manually, 
and is repeatable in a different device. The valid value ranges from 0 to 256 by 
default. 

Pulse Width(us) 

The time width represents the changes of the quantity of electric charge with 
high-frequency capacitance regularly within a specified time. 

Pulse Interval(us) 

The time interval between pulses. 

ID Type 

Select between User ID and badge number. 

 

 

 

Summary of Contents for Green Label ProFace X

Page 1: ...r Manual P a g e 1 Copyright 2020 ZKTECO CO LTD All rights reserved User Manual ProFace X TD Version 1 0 Date April 2020 www rassecurity com www ais security be ras contact rassecurity com ais contact...

Page 2: ...the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equipm...

Page 3: ...e unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible i in case the machine unit equipment ma...

Page 4: ...t research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication field...

Page 5: ...tion Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are sep...

Page 6: ...CATION 22 2 MAIN MENU 23 3 USER MANAGEMENT 25 ADDING USERS 25 3 1 SEARCH FOR USERS 29 3 2 EDIT USERS 30 3 3 DELETING USERS 30 3 4 4 USER ROLE 31 5 COMMUNICATION SETTINGS 34 NETWORK SETTINGS 34 5 1 PC...

Page 7: ...INGS 66 9 6 10 ATTENDANCE SEARCH 67 11 AUTOTEST 70 12 SYSTEM INFORMATION 71 13 CONNECT TO ZKBIOACCESS EP SOFTWARE 72 SET THE COMMUNICATION ADDRESS 72 13 1 ADD DEVICE ON THE SOFTWARE 73 13 2 ADD PERSON...

Page 8: ...ion Facial Expression and Standing 1 1 Posture The recommended distance Facial expression and standing posture The distance between the device and a user whose height is within 1 55m 1 85m is recommen...

Page 9: ...rved Note During enrolment and verification please remain natural facial expression and standing posture Palm Registration 1 2 Place your palm in the palm multi mode collection area such that the palm...

Page 10: ...ot follow the instructions on the screen the face registration may take longer or may fail Be careful not to cover the eyes or eyebrows Do not wear hats masks sunglasses or eyeglasses Be careful not t...

Page 11: ...ce Standby Interface 1 4 After connecting the power supply enter the following standby interface Notes 1 Click to enter the User ID input interface 2 When there is no super administrator set in the de...

Page 12: ...d 1 5 Note The device supports the input of Chinese English numbers and symbols Click En to switch to English keyboard Press 123 to switch to the numeric and symbolic keyboard and click ABC to return...

Page 13: ...ector with all the palm data in the device The device will automatically distinguish between the palm and the face verification mode and place the palm in the area that can be collected by the palm co...

Page 14: ...O LTD All rights reserved If the user has registered the face and password in addition to his her palm and the verification method is set to palm face password verification the following screen will a...

Page 15: ...he entered password with the registered User ID and password Click the button on the main screen to enter the 1 1 password verification mode 1 Input the user ID and press OK If an employee registers p...

Page 16: ...ProFace X TD User Manual P a g e 15 Copyright 2020 ZKTECO CO LTD All rights reserved 2 Input the password and press OK...

Page 17: ...ProFace X TD User Manual P a g e 16 Copyright 2020 ZKTECO CO LTD All rights reserved Verification is successful Verification is failed...

Page 18: ...ZKTECO CO LTD All rights reserved 1 6 3 Facial Verification 1 N Facial Verification 1 Conventional verification Compare the acquired facial images with all face data registered in the device The follo...

Page 19: ...ventional verification method the user s face must be aligned with the temperature measurement area to measure the body temperature before the verification can be conducted The following is a popup of...

Page 20: ...TECO CO LTD All rights reserved 1 1 Facial Verification Compare the face captured by the camera with the facial template related to the entered user ID Press on the main interface and enter the 1 1 fa...

Page 21: ...ser Manual P a g e 20 Copyright 2020 ZKTECO CO LTD All rights reserved If an employee registers palm and password in addition to face the following screen will appear Select the icon to enter face ver...

Page 22: ...anual P a g e 21 Copyright 2020 ZKTECO CO LTD All rights reserved After successful verification the prompt box successfully verified will appear If the verification is failed it will prompts Please ad...

Page 23: ...rification methods A total of 7 different verification combinations can be used as shown below Notes 1 means or and means and 2 You must register the required verification information before using the...

Page 24: ...operate the system COMM To set the relevant parameters of network PC connection cloud server and wiegand System To set parameters related to the system including date time access records facial templ...

Page 25: ...earch Query the specified access record check attendance photos and blacklist photos Autotest To automatically test whether each module functions properly including the screen audio camera and real ti...

Page 26: ...e main menu Click New User Register a User ID and Name Enter the user ID and name Notes 1 A user name may contain 17 characters 2 The user ID may contain 1 9 digits by default 3 During the initial reg...

Page 27: ...nistrator owns all management privileges If a custom role is set you can also select user defined role permissions for the user Click User Role to select Normal User or Super Admin Note If the selecte...

Page 28: ...ce registration page Please face the camera and stay still during face registration The registration interface is as follows Register password Click Password to enter the password registration page En...

Page 29: ...the system will automatically capture a picture as the user photo If you do not want to register a user photo the system will automatically set the picture captured as the default photo Access Control...

Page 30: ...ht 2020 ZKTECO CO LTD All rights reserved Search for Users 3 2 Click the search bar on the user list and enter the retrieval keyword The keyword may be an ID surname or full name The system will searc...

Page 31: ...n of editing a user is the same as that of adding a user except that the user ID cannot be modified when editing a user Operation method refers to 3 1 Adding users Deleting Users 3 4 Choose a user fro...

Page 32: ...edit the User Defined Role under the User Role menu You may set the permission scope of the custom role up to 3 roles and enroller that is the permission scope of the operation menu Click User Role on...

Page 33: ...ProFace X TD User Manual P a g e 32 Copyright 2020 ZKTECO CO LTD All rights reserved 2 Click Define User Role to assign the privileges to the role The privilege assignment is completed Click Return...

Page 34: ...eft and its sub menus are on the right You only need to select the features in sub menus If the device has a role enabled you may assign the roles you set to users by clicking User Mgt New User User R...

Page 35: ...the network PC connection cloud server and Wiegand TapCOMM on the main menu Network Settings 5 1 When the device needs to communicate with a PC over the Ethernet you need to configure network settings...

Page 36: ...situation Gateway The factory default address is 0 0 0 0 Please adjust them according to the actual network situation DNS The factory default address is 0 0 0 0 Please adjust them according to the act...

Page 37: ...software Click PC Connection on the Comm Settings interface Item Descriptions Comm Key Comm Key The default password is 0 which can changed The Comm Key may contain1 6 digits Device ID Identity numbe...

Page 38: ...www XYZ com while XYZ denotes the domain name when this mode is turned ON Disable Domain Name Server Address IP address of the ADMS server Server Port Port used by the ADMS server Enable Proxy Server...

Page 39: ...e adjusted within the range of 20 to 100 microseconds Pulse Interval us The default value is 1000 microseconds which can be adjusted within the range of 200 to 20000 microseconds ID Type Select betwee...

Page 40: ...CCCCCCCCCCO Consists of 36 bits of binary code The 1st bit is the even parity bit of the 2nd to 18th bits while the 36th bit is the odd parity bit of the 19th to 35th bits The 2nd to 19th bits are the...

Page 41: ...igitsin the Wiegand format Failed ID If the verification is failed the system will send the failed ID to the device and replace the card number or personnel IDwith the new ones Site Code It is similar...

Page 42: ...System on the main menu interface Date and Time 6 1 Click Date Time on the System interface 1 You can manually set date and time and click Confirm to save 2 Click 24 Hour Time to enable or disable th...

Page 43: ...are 5 modes No Photo No photo is taken during user verification Take photo no save Photo is taken but is not saved during verification Take photo and save Photo is taken and saved during verification...

Page 44: ...a set value of old attendance photos Users may disable the function or set a valid value between 1 and 99 Cyclic Delete Blacklist Photo When blacklisted photos have reached full capacity the device w...

Page 45: ...face has already been registered Face Pitch Angle The pitch angle tolerance of a face for facial registration and comparison If a face s pitch angle exceeds this set value it will be filtered by the...

Page 46: ...revent fake photos and videos attack WDR Wide Dynamic Range WDR which balances light and extends image visibility for surveillance videos under high contrast lighting scenes and improves object identi...

Page 47: ...right 2020 ZKTECO CO LTD All rights reserved Factory Reset 6 5 Restore the device such as communication settings and system settings to factory settings Do not clear registered user data Click Reset o...

Page 48: ...or shut down Click Temperature Mgt on the System interface Item Description Real time temperature This column shows real time inner temperature of terminal Low Temp to Heat Once terminal temperature...

Page 49: ...identity verification To measure body temperature users faces must be aligned with the temperature measurement area High temperature alarm threshold To set the value of the alarm threshold of high bo...

Page 50: ...t module allows a small range of errors disturbance of an observed value under different environments humidity room temperature and such users may set the deviation value here Temp Unit The unit of bo...

Page 51: ...rights reserved 7 Personalize Settings You may customize interface settings audio and bell Click Personalize on the main menu interface Interface Settings 7 1 You can customize the display style of t...

Page 52: ...Show s When there is no operation and the time exceeds the set value a slide show will be played It can be disabled or you may set the value between 3 and 999 seconds Slide Show Interval s This refers...

Page 53: ...Click Voice on the Personalize interface Item Description Voice Prompt Select whether to enable voice prompts during operating Touch Prompt Selectwhether to enable keypad sounds Volume Adjust the volu...

Page 54: ...cycle of the bell Ring Tone Select a ring tone Internal bell delay s Set the duration of the internal bell Valid values range from 1 to 999 seconds 2 Back to the Bell Schedules interface click All Bel...

Page 55: ...ut Auto Mode After this mode is chosen set the switching time of punch state key in Shortcut Key Mappings when the switching time is reached the set punch state key will be switched automatically Mana...

Page 56: ...hortcut Keys Mappings 7 5 Users may define shortcuts as attendance status or functional keys On the main interface when the shortcut keys are pressed the corresponding attendance status or function in...

Page 57: ...8 1 Click Delete Data on the Data Mgt interface Item Description Delete Access Records To delete attendance data access records conditionally Delete Attendance Photo To delete attendance photos of de...

Page 58: ...hotos in the device Delete Wallpaper To delete all wallpapers in the device Delete Screen Savers To delete the screen savers in the device Note When deleting the access records attendance photos or bl...

Page 59: ...ccess the registered user must meet the following conditions 1 The current door unlock time should be within any valid time zone of the user time period 2 The user s group must be in the door unlock c...

Page 60: ...device controls the electric lock to be unlock Valid value 1 10 seconds 0 second represents disabling the function Door Sensor Delay s If the door is not closed and locked after opening for a certain...

Page 61: ...is closed or the verification is successful the system will cancel the alarm from the local Reset Access Setting The restored access control parameters include door lock delay door sensor delay door...

Page 62: ...ProFace X TD User Manual P a g e 61 Copyright 2020 ZKTECO CO LTD All rights reserved 2 Click the date on which time zone settings is required Enter the starting and ending time and then press OK...

Page 63: ...ve time period to unlock the door open all day 00 00 23 59 or when the ending time is later than the starting time such as 08 00 23 59 3 The default time zone 1 indicates that door is open all day lon...

Page 64: ...item to be deleted and click Delete Click OK to confirm deletion After deletion this holiday is no longer displayed on All Holidays interface Combined Verification Settings 9 4 Access groups are arra...

Page 65: ...ination 2 is set as 02 02 04 04 07 indicating that the unlocking combination 2 consists of 5 people the first two are from AC group 2 the next two are from AC group 4 and the last person is from AC gr...

Page 66: ...master device and slave device must be consistent Click Anti passback Setup on the Access Control interface Item Description Anti passback direction No Anti passback Anti passback function is disabled...

Page 67: ...door as usual but at the same time a signal will be sent to trigger the alarm Click Duress Options on the Access Control interface Item Description Alarm on Password When a user uses the password veri...

Page 68: ...be saved in the device This function enables users to check their access records Click Attendance Search on the main menu interface The process of searching for attendance and blacklist photos is sim...

Page 69: ...ht 2020 ZKTECO CO LTD All rights reserved 1 Enter the user ID to be searched and click OK If you want to search for records of all users click OK without entering any user ID 2 Select the time range i...

Page 70: ...TD User Manual P a g e 69 Copyright 2020 ZKTECO CO LTD All rights reserved 3 The record search succeeds Click the record in green to view its details 4 The below figure shows the details of the select...

Page 71: ...automatically test the display effect of LCD screen by displaying full color pure white and pure black to check whether the screen displays colors normally Test Voice To automatically test whether the...

Page 72: ...on the main menu interface Item Description Device Capacity Displays the current device s user storage palm password and face storage administrators access records attendance and blacklist photos and...

Page 73: ...o communicate with the ZKBioAccess EP server preferably in the same network segment with the server address 2 In the main menu click COMM Cloud Server Setting to set the server address and server port...

Page 74: ...are 13 2 Add device by searching The process is as follows 1 Click Access Control Device Search Device to open the Search interface 2 Click Search and it will prompt Searching 3 After searching the li...

Page 75: ...served Add Personnel on the Software 13 3 1 Click Personnel Person New 2 After setting all parameters click OK Real time monitoring on the Software 13 4 1 Click Prevention Epidemic Real time monitorin...

Page 76: ...arm temperature setting has set the abnormal body temperature will be marked red automatically 2 Click Epidemic Statistics panel to view the analysis of statistical data and view the personnels with n...

Page 77: ...d for registration 4 Please show your face and forehead and do not cover your face and eyebrows with your hair 5 It is recommended to show a plain facial expression Smile is acceptable but do not clos...

Page 78: ...apturing Eye Distance 200 pixels or above are recommended with no less than 115 pixels of distance Facial Expression Plain face or smile with eyes naturally open are recommended Gesture and Angel Hori...

Page 79: ...ressed image with not more than 20kb size 4 Definition rate between 358 x 441 to 1080 x 1920 5 The vertical scale of head and body should be 2 1 6 The photo should include the captured person s should...

Page 80: ...issues concerning your use of our product please directly contact your dealer Our other law enforcement fingerprint devices or development tools can capture the original images of citizen s fingerpri...

Page 81: ...onent Name Hazardous Toxic Substance Element Lead Pb Mercury Hg Cadmiu m Cd Hexavalent chromium Cr6 Polybrominate d Biphenyls PBB Polybrominated Diphenyl Ethers PBDE Chip Resistor Chip Capacitor Chip...

Page 82: ...www rassecurity com www ais security be ras contact rassecurity com ais contact ais security be...

Reviews: