10.2 Time Rule Settings
Time Rule
is the minimum time unit of access control settings; at most 50
Time Rule
can be set
for the system. Each
Time Rule
consists of 7 time sections (a week) and 3 holiday time schedules,,
and each time section is the valid time within 24 hrs.
You may set a maximum of 3 time periods for every time schedule. The relationship among these
time periods is "or". When the verification time falls in any one of these time periods, the
verification is valid. The time period format is HH:MM-HH:MM in the 24-hour system with precision
to minute.
When the device is on the initial interface, press
button >
Access Control
>
Time Rule
setting
to enter the
Time Rule setting
interface. The default
Time Rule
No. is 1 (whole-day valid),
which can be edited.
z
Editing a Time Rule
A super administrator may edit time rules as needed. The detailed operation is as follows:
Input time rule number (such as
“2”), the time rule (2) will be
located automatically, select a
time schedule (such as
“Monday”).
Select “Time Period 1/2/3”
and enter time period setting
interface.
Set “Start Time” and “End Time”
as required, after setting, press
[Confirm(OK)]
to save and exit.