BG2000 Series Barrier Gate (APP Version)
User Manual
P a g e
| 21
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Parameter Settings Description
Ites
Description
De
fa
u
lt
(
1.5m
boom
)
De
fa
u
lt
(
2m
boom
)
De
fa
u
lt
(
3m
boom
)
De
fa
u
lt
(
4m
boom
)
01EXXX
Display Mode
01E000: Displays current position of the
swing arm
01E001: Controls input signal
01E002: Test mode (the digital LED
displays "---" in the test mode)
01E102: Opening position
01E202: Closing position
01E502: Opening
01E602: Closing
01E702: In the pause
01E003: Number of boom openings
01E004: Version Information
01E000
01E000
01E000
01E000
02EXXX
Boom Arm Opening Speed
02E000: Low
02E001: Medium
02E002: Fast
02E003: Very Fast
Adjust the corresponding speed according
to the boom arm length.
02E003
02E003
02E003
02E001
03EXXX
Boom Arm Opening Brake Stroke
The larger the number, the longer the
deceleration time and the more stable the
boom arm operation. The Boom Arm
Opening Deceleration Distance can be set
between 10 to 25 and the default value is
20.
03E018
03E022
03E021
03E025
04EXXX
Boom Arm Opening Brake Speed
The smaller the number is, the slower the
deceleration, valid value: 2 to 30.
04E015
04E024
04E027
04E030
05EXXX
Boom Arm Closing Speed
05E000: Low
05E001: Medium
05E002: Fast
05E003: Very Fast
Adjust the corresponding speed according
to the boom arm length.
05E003
05E003
05E003
05E001