ZK-RFID102 UHF RFID Reader User's Manual V2.0
8
4.2 18000-6B COMMAND
NUM
COMMAND
CODE
CONNECT
1
Inventory signal 6B
0x50
The function is used to Inventory only one tag in the effective
field and get their ID values. If more than one tag in the
effective field at the same time, reader may be get nothing.
2
Inventory multiple 6B
0x51
The function is used to according to the given conditions
Inventory tags in the effective field and get their ID values.
3
Read Data 6B
0x52
The function is used to start to read several bytes from the
designated address.
4
Write Data 6B
0x53
The function is used to start to write several bytes from the
designated address.
5
Check Lock 6B
0x54
The function is used to check whether the designated byte is
locked.
6
Lock 6B
0x55
The function is used to lock the designated byte.
4.3 READER DEFINED COMMAND
NUM
COMMAND
CODE
CONNECT
1
GetReader
Information
0x21
This function is used to get reader-related information such as
reader address (Adr), firmware version, supported protocol
type, Inventory ScanTime, power and frequency.
2
Set Region
0x22
Sets the current region. The function is used to set the reader
working of the lower limit and the upper limit of frequency.
3
Set Address
0x24
This function is used to set a new address of the reader. The
address value will store in reader’s inner nonvolatile memory.
Default address value is 0x00. The value range is 0x00~0xFE.
The address 0xFF is reserved as the broadcasting address.
When user tries to write a 0xFF to Adr, the reader will set the
value to 0x00 automatically.
4
Set ScanTime
0x25
This function is used to set a new value to Inventory ScanTime
of an appointed reader. The range is 3~255 corresponding to
3*100ms~255*100ms Inventory ScanTime. The default value
of Inventory ScanTime is 10*100ms.
5
Set Baud Rate
0x28
The function is used to change the serial port baud rate.
6
Set Power
0x2F
The function is used to set the power of reader.
7
Acousto-optic Control 0x33
Acousto-optic Control
8
Set Wiegand
0x34
The function is used to set Wiegand parameter.
9
Set WorkMode
0x35
The function is used to set work mode parameter.
10
Get WorkMode
0x36
The function is used to get work mode parameter.
11
SetEasAccuracy
0x37
The function is used to set EasAlarm Accuracy.
12
Syris Response Offset
0x38
The function is used to set Syris485 response offset time.
13
Trigger Offset
0x3b
The function is used to set Trigger Offset time.