8.4.5 Set Band Rate
The host sends this command to change the value of band rate of the reader. The value is stored in the
reader’s inner EEPROM and is nonvolatile after reader powered off.
Command:
Len
Adr
Cmd
Data[]
CRC-16
BaudRate
0x05
0xXX
0x28
0xXX
LSB
MSB
Parameter Connect:
BaudRate:
The serial port baud rate default value is 57600 bps. Defined as follows:
BaudRate
Bps
0
9600bps
1
19200 bps
2
38400 bps
5
57600 bps
6
115200 bps
Respond:
Len
Adr
reCmd
Status
Data[]
CRC-16
0x05
0xXX
0x28
0x00
——
LSB
MSB
Notes: The response of the baud rate for the original baud rate, and next command uses the new band rate.
8.4.6 Set Power
The host sends this command to change the power of the reader. The value is stored in the reader’s inner
EEPROM and is nonvolatile after reader powered off.
Command:
Len
Adr
Cmd
Data[]
CRC-16
Pwr
0x05
0xXX
0x2F
0xXX
LSB
MSB
Parameter Connect:
Pwr:
New power. The default value is 30(about 30dBm), it range is 0~30.
Respond:
Len
Adr
reCmd
Status
Data[]
CRC-16
0x05
0xXX
0x2F
0x00
——
LSB
MSB