background image

1

inPulse & and ZKBioSecurity 3.0 Quick Start Guide

Quick Start Guide

inPulse & 

+

ZKBioSecurity 3.0

Summary of Contents for inPulse

Page 1: ...1 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide QuickStartGuide inPulse inPulse ZKBioSecurity3 0 ...

Page 2: ...alone Installation 12 Third Party Controller 13 How does inPulse inPulse works 14 Registration andVerification 15 Device Operation 16 ZKBioSecurity 3 0 Downloading 20 Installation 21 Adding Device 23 Creating aTime Zone 25 Creating an Access Level 26 Enrolling Personnel 27 Wiegand Format 29 Add Delete Personnel to Access Level 30 Real Time Monitoring 31 Exporting Reports 32 ZKBioSecurity Software ...

Page 3: ...Ts TVs monitors or speakers may dam age the device Do not place the device next to heating equipment Be careful not to let liquid like water drinks or chemicals leak inside the device Do not let children touch the device without supervision Do not drop or damage the device Do not disassemble repair or alter the device Do not use the device for any other purpose than specified Clean the device ofte...

Page 4: ...4 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide Device Overview Not all products have fingerprint and finger vein functions inPulse inPulse ...

Page 5: ...ce Overview 12 Pin Cable Connector 7 Pin Cable Connector 8 Pin Cable Connector Tamper Alarm Button 2 Pin Cable Connector 4 Pin Cable Connector Ethernet TCP IP Auxiliary In Bell Sensor Button Lock Alarm Power Out Wiegand In LED Beep Wiegand Out RS232 RS485 Power In ...

Page 6: ...the Device on the Wall Fix the back plate onto the wall using wall mounting screws Note We recommend drilling the mounting plate screws into solid wood i e stud beam If a stud beam cannot be found use supplied drywall plastic anchors Use security screws to fasten the device to back plate Insert the device to back plate ...

Page 7: ... and ZKBioSecurity 3 0 Quick Start Guide Power Connection Without UPS With UPS Optional Recommended Power Supply 12V 10 at least 500mA To share the power with other devices use a power supply with higher current ratings ...

Page 8: ...8 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide Ethernet Connection Note The device can be connected to PC directly by Ethernet cable LAN Connection Ethernet cable Network Cable Apator ...

Page 9: ... the NO LOCK normally opened at power on is connected with NO1 and COM1 terminals and the NC LOCK normally closed at power on is connected with NC1 and COM1 terminals 2 When electrical lock is connected to the Access Control System you must parallel one FR107 diode equipped in the package to prevent the self inductance EMF from affecting the system Do not reverse the polarities ...

Page 10: ...10 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide Lock Relay Connection Device Sharing Power with the Lock ...

Page 11: ...11 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide Wiegand Output Connection ...

Page 12: ...12 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide Standalone Installation ...

Page 13: ...13 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide Third Party Controller Wiegand Output Connection ...

Page 14: ...14 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide How does inPulse inPulse works or or or ...

Page 15: ...in reader Verification Steps Touch the front side of finger vein reader with fingertip then press your finger upon the finger vein reader Place the finger according to the finger guide Finger tip must touch the front of finger vein reader in order to properly collect fingerprint and finger vein images Touch the reader with finger root Improper positioning of finger will affect the proper collectio...

Page 16: ...ngerprint Fingervein badge number password and setting access control role Ethernet Settings Press icon to enter the Main Menu Comm Ethernet The parameters below are the system default values Please adjust them according to the actual network IP Address 192 168 1 201 Subnet Mask 255 255 255 0 Gateway 0 0 0 0 DNS 0 0 0 0 TCP COMM Port 4370 DHCP Dynamic Host Configuration Protocol which dynamically ...

Page 17: ...rol Settings Press icon to enter the Main Menu press and to select Access Control To gain access the registered user must meet the following conditions 1 User s access time must fall within either user s personal time zone or group time zone 2 User s group must be in the access combo when there are other groups in the same access combo verification of members of those groups are also required to u...

Page 18: ... all group number to zero to reset access control combination Troubleshooting 1 Invalid time zone is displayed after verification Contact Administrator to check if the user has the privilege to gain access within that time zone 2 Verification succeeds but the user cannot gain access Check whether the user privilege is set correctly Check whether the lock wiring is correct 3 The Tamper Alarm rings ...

Page 19: ...etup It is recommended to install software version 3 0 3 0 or above Downloading 20 Installation 21 Adding Device 23 Creating aTime Zone 25 Creating an Access Level 26 Enrolling Personnel 27 Wiegand Format 29 Add Delete Personnel to Access Level 30 Real Time Monitoring 31 Exporting Reports 32 ...

Page 20: ...ick Start Guide Downloading 1 Go to http www zkteco com product ZKBioSecurity3 0_421 html 2 Download the latest software and related files as required 3 Once downloaded extract the rar file to a new folder 4 Click on setup to begin installstion ...

Page 21: ... to install the software Click Continue if all tests are passed else check the issues and re test 2 Add an open port Default 8088 or ask a network administrator for an open port Note Stanalone device doesn t support https 3 Click the check box to add firewall exception for this port Installation ...

Page 22: ...tallation 4 Select the mode of database The default will be PostgreSQL if you want to select any other database then select Alternative database 5 Click Browse and choose or create a folder to store your backup files 6 Select Create the required folder 7 Click OK ...

Page 23: ...Guide 1 Click on Access to get below interface of Access Module of the software Adding Device 2 Click on Device 3 Click on Search Device 4 Click Search to search all the sandalone devices on the network 5 From the list click Add to add the required device ...

Page 24: ...dify the IP address as shown below Adding Device 7 Enter the IP address of current system PC 8 Enter the access point of system 9 Click on this option after adding device the system will clear all data in the device except the event logs 10 Click OK to finish When the device is not in the same network with server customers should down load the tool and search the device as shown below ...

Page 25: ...nPulse and ZKBioSecurity 3 0 Quick Start Guide Creating aTime Zone Click Access Control Time Zones Add to access the time zone After setting the time zone click OK to save and the time zone will appear in the list ...

Page 26: ...eating an Access Level 1 Click Access 2 Click Access Control 3 Click Access Levels 4 Click New 5 Enter the details and click OK 6 You need to add doors to the access levels 7 Select the required door s 8 Move the selected door s 9 Click OK to finish adding doors ...

Page 27: ...onnel 2 Click Person 3 Click New to add personnel A Personnel ID It must be a unique 9 characters length with the valid range of 1 79999999 It can be configured based on actual conditions The Person nel No contains only numbers by default but may also include letters after setting parameters ...

Page 28: ...umber You can add a card number through manual entry or a card issuer For issuing through issuer click on the card icon directly For issu ing card manually you must enter both the card number and the site code then the software converts the numbers to the card number for access con trol system verification E Access Control Here you will get all the access levels created by you and by default Tick ...

Page 29: ...o modes for adding Wiegand Format if mode 1 does not meet your setting requirement switch to mode 2 1 Click Personnel 2 Click Card Management 3 Click Wiegand Format 4 Taking Wiegnad Format34 as an example Click to edit p indicates Parity Position s indicates Site Code c indicates Cardholder ID f in dicates Facility Code m indicates Manufactory Code e indicates Even Parity O indicates Odd Parity b ...

Page 30: ...cess Level 1 Click Access 2 Access Control 3 Set Access by Person 4 Click on the required employee 5 Click Add to Levels 6 Select Level s 7 Click to move the selected level s to the right and then click OK to complete adding The added level s will appear in the list on to the right side ...

Page 31: ...tus and real time events of standalone in the system including normal events and abnormal events including alarm events device transactions You can also filter by Area device name Serial number to check a specific de vice transactions or all at once Hover over a door icon to open pop up menu as shown below and click Re mote Closing Remote Opening or Cancel Alarm and more ...

Page 32: ... Personnel ID Device Name and more if required and click on search 4 Click All transactions or as required 5 Click on Export to get the list 6 Click OK 1 Click Personnel 2 Click Person 3 Filter the data Department Personnel ID and more if required and click on search 4 Click on Export to get the list Access Module Personnel Module ...

Page 33: ...33 inPulse inPulse and ZKBioSecurity 3 0 Quick Start Guide ZKAccess division of ZKTeco 6 Kingsbridge Road Suite 8 Fair eld NJ 07004 T 1 862 505 2101 sales zkaccess com www zkaccess com ...

Reviews: