background image

 

Battery charger BC1 

 

D01001-02

 

 

3

 

 

 

Installation and safety instructions 

Battery charger BC1 has been designed to provide safety and reliable. It is necessary to observe the 
following precautions in order to avoid damage to persons and to the battery charger: 

• 

Read the installation instructions contained in this Manual carefully. For further information put the 
Manual in a proper place. 

• 

Fix the battery charger to a stable surface through the appropriate holes inserted on the fixing 
flanges. In case of installation on a vehicle it is advisable to use antivibration supports. 

• 

Preferably the charger should be installed in the vertical position with the fan facing up. The 
horizontal installation is allowed. Never install in the vertical position  with the fan facing down. 

• 

Ensure all ventilation ports are not obstructed, to avoid the overheating. Do not put the battery 
charger near heat sources. Make sure that free space around the battery charger is sufficient to 
provide adequate ventilation and an easy access to cables sockets. 

• 

Protect the battery charger from ingress of water. Do not pour liquids inside the case. 

• 

Verify that the available supply voltage corresponds to the voltage that is stated on the battery 
charger name plate. In case of doubt, consult a retailer or local Electric Supply Authority. 

• 

For safety and electromagnetic compatibility, the battery charger has a 3-prong  plug as a safety 
feature, and it will only fit into an earthed outlet. If you can not plug it in, chances are you have an 
older, non-earthed outlet; contact an electrician to have the outlet replaced. Do not use an adapter to 
defeat the earthing. 

• 

To avoid damaging the power cord, do not put anything on it or place it where it will be walked on. If 
the cord becomes damaged or frayed, replace it immediately. 

• 

If you are using an extension cord or power strip, make sure that the total of the amperes required by 
all the equipment on the extension is less than the extension’s rating. 

• 

Disconnect the mains supply before connecting or disconnecting the links to the battery. 

• 

To recharge Lead Acid batteries: WARNING: Explosive Gas – Avoid flames and sparks. The battery 
must be positioned in a correctly cooled place. 

• 

Do not use to charge batteries installed on board of thermal engine cars. 

• 

Avoid recharging of non-rechargeable batteries. 

• 

Verify that the nominal voltage of the battery to be re-charged corresponds to the voltage stated on 
the battery charger name plate. 

• 

Verify that the selected charging curve is suitable for the type of battery to be re-charged. In case of 
doubt, consult Your retailer. ZIVAN S.r.l. will not accept any responsibility in case of mistaken choice 
of the charging curve that may cause irreversible damage to the battery. 

• 

In order to avoid voltage drop, thereby assuring 100% charge at the battery, the output cables must 
be as short as possible, and the diameter must be adequate for the output current. 

• 

Do not try to service the battery charger yourself. Opening the cover may expose you to shocks or 
other hazards. 

• 

If the battery charger does not work correctly or if it has been damaged, unplugged it immediately 
from the supply socket and from the battery socket and contact a retailer. 

Summary of Contents for BC1

Page 1: ...BATTERY CHARGER BATTERY CHARGER BC1 Installation and User Manual...

Page 2: ...er to the presence of important operating and maintenance servicing instructions in the literature accompanying the equipment This product is covered by warranty The relative warranty certificate is a...

Page 3: ...you have an older non earthed outlet contact an electrician to have the outlet replaced Do not use an adapter to defeat the earthing To avoid damaging the power cord do not put anything on it or place...

Page 4: ...er stops supplying current Battery A battery is characterised by two sizes tension and capacity Tension Each element has a nominal tension which depends on the type of battery no matter what size In o...

Page 5: ...arger BC1 D01001 02 5 6 105 12 5 285 260 12 5 50 Mechanical dimensions 245 285 45 75 75 105 N B All dimensions are expressed in mm Drilling details UP Advised Installation N B All dimensions are expre...

Page 6: ...Symbol Test Condition Value and or Range Unit Output current ripple I I1 5 Absorbed current Ia Equipment turned off 1 mA Output voltage ripple U U1 1 Maximum power supplied Pmax U U1 I I1 720 W Outpu...

Page 7: ...Inside the equipment 10 delayed A Output fuse F2 Inside the equipment 40 A Minimum output voltage of operation Battery Detector Equipment turn on 1 3 V cell Reverse output polarity At the connection...

Page 8: ...net presence 2 Normally closed contact for mains presence 3 Normally opened contact for mains presence 4 Red LED anode 5 Common cathode LED 6 Green LED anode Technical features exchange contacts 0 3A...

Page 9: ...d LED anode 2 Not used 3 Common cathode LED 4 Green LED anode Connector 2 poles Pin Use 1 Common contact net presence 2 Normally closed contact for mains presence Technical features exchange contacts...

Page 10: ...582482 Fax 39 040 232440 Fax 31 55 5222366 Fax 44 1 952 581377 U S A GERMANY SPAIN ELECTRIC CONVERSIONS ATECH Antriebstechnik GmbH VARELEC SCCL 215 14th Sreet Gewerbepark Lindach D7 c Lope de Vega 10...

Page 11: ...Battery charger BC1 D01001 02 11...

Page 12: ...ttery charger BC1 D01001 02 12 Electric Conversions Distributor of ZIVAN Battery Chargers 215 14th Street Sacramento CA 95814 Tel 916 441 4161 Fax 916 444 8190 E mail elcon jps net Web www zivanusa co...

Reviews: