Addressable point detectors 

 

Model 

Type 

MFG code 

Description 

DP951 

ODx 

55000-620 

950 Series optical detector 

DP951B 

ODx 

55000-660 

950 Series black optical detector 

DP951T 

OHDx 

55000-885 

950 Series optical/heat detector 

DT952 

HDx 

55000-420 

950 Series temperature detector 

DT953 

HDx 

55000-401 

950 Series high temperature detector 

DI950 

IDx 

55000-520 

950 Series ionisation sensor 

DP991 

ODd 

58000-600 

990 Series discovery optical detector 

DP991T 

OHDd 

58000-700 

990 Series multisensor 

DT992 

HDd 

58000-400 

990 Series heat detector 

 

Addressable zone detectors 

 

Model 

Type 

MFG code 

Description 

FD905R 

BDx 

55000-268 

950 Series reflective beam detector (5 to 50 m) 

FD910R 

BDx 

55000-273 

950 Series reflective beam detector (50 to 100 m) 

 

Addressable I/O modules 

 

Model 

Type 

MFG code 

Description 

II950I 

SIMx 

55000-760 

950 Series mini switch monitor with isolator 

II952D 

SIMx 

55000-822 

950 Series switch monitor with DIN rail mount 

II952I 

SIMx 

55000-843 

950 Series switch monitor with isolator 

II953D 

SIMx 

55000-821 

950 Series switch monitor plus with DIN rail mount 

II953I 

SIMx 

55000-841 

950 Series switch monitor plus with isolator 

II955D 

1ZMx 

55000-812 

950 Series zone monitor unit with isolator and DIN 
rail mount 

II955I 

1ZMx 

55000-845 

950 Series zone monitor unit with isolator 

IO950I 

IOx 

55000-847 

950 Series I/O unit with isolator 

IO953I 

IOx 

55000-588 

950 Series 3-channel I/O with isolator and 
protective housing 

IO954 

IOx 

55000-875 

950 Series mains switching unit 

IO955I 

IOx 

55000-849 

950 Series output unit with isolator 

IO956CD 

SDx 

55000-182 

950 Series sounder circuit controller with DIN rail 
mount (CPD certified) 

IO956I 

SDx 

55000-852 

950 Series, sounder circuit controller with isolator 

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for ZP2 Series

Page 1: ...900 Series Protocol Guide for ZP2 Series Control Panels www acornfiresecurity com www acornfiresecurity com...

Page 2: ...n 1 Intended audience and purpose 1 Firmware compatibility 1 Installation 2 Registering the 2010 2 PAK 900 2 Connecting loop devices 3 Configuration 4 Detector configuration 4 Sounder configuration 5...

Page 3: ...ts essential purpose Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory While every precaution has been taken during th...

Page 4: ...ormation on topics not specific to the 900 Series protocol see your control panel installation and operation manuals Firmware compatibility Information in this document covers control panels with firm...

Page 5: ...s to confirm the registration 5 Press Apply to apply the registration details to the panel or Continue to register more PAKs for the same control panel To apply the 900 Series protocol 1 Remove the PA...

Page 6: ...l and then press the jog dial to confirm the selection 4 When the update is complete remove the jumper from JP4 and then press Reboot to restart the control panel The control panel is now configured t...

Page 7: ...sponding loop and device The loop device configuration menu displays 3 Select Base and then select YES to enable the detector base 4 Press F4 Enter and then press F1 Back 5 Press F1 Save F3 Apply F4 D...

Page 8: ...ld setup from the Main menu and then select Loop device config 2 Select the corresponding loop and device The loop device configuration menu displays 3 Select act_grp and then assign the required grou...

Page 9: ...magnetic wand to locally test each of the loop sounders 3 When you have finished press the jog dial again to exit loop walk test mode 4 Press F1 Back or F2 Exit Adjusting the volume Select Snd volume...

Page 10: ...ration 1 Select Field setup from the Main menu and then select Loop device config 2 Select the corresponding loop and device The loop device configuration menu displays 3 Select and check Radio to ena...

Page 11: ...N A 45681 215 970 Series IS detector base Addressable manual call points Model Type MFG code Description DM950BI D MCPx 245663 950 Series blue manual call point with isolator aluminum DM950I D MCPx 2...

Page 12: ...escription II950I SIMx 55000 760 950 Series mini switch monitor with isolator II952D SIMx 55000 822 950 Series switch monitor with DIN rail mount II952I SIMx 55000 843 950 Series switch monitor with i...

Page 13: ...NEN SDx 55000 276 950 Series 100 dB loop powered standalone sounder slow whoop AS967I SDx 55000 005 950 Series intelligent loop powered open area red sounder beacon with isolator AS967WRCI SDx 55000 0...

Page 14: ...D detectors Wireless devices Model Type MFG code Description II955IRF ZMx XPA IN 14007 APO Xpander zone monitor unit with isolator DT934RF HDx XPA CB 11170 APO Xpander A1R heat detector DT937RF HDx XP...

Page 15: ...55000 440 970 Series addressable IS heat detector DB970 N A 45681 215 970 Series IS detector base GBX70 N A 29600 098 950 Series IS galvanic barrier PT971 N A 55000 855 970 Series IS 1 channel protoc...

Reviews: