35
EN
TROUBLESHOOTING
CAUTION! Opening the housing of the device without a prior contact with a manufacturer’s service
voids the warranty.
If you suspect a failure that requires the housing to be opened, contact manufacturer’s
service.
Error description
Possible causes
Solution
-----
Safety key issue
The safety key is not connected.
Connect the safety key correctly.
The computer is damaged.
Contact manufacturer's service.
E01
The computer does not
work
The computer is incorrectly
connected.
Verify the connection of computer cables.
The signal cable is broken or
insulation is worn
Verify plug connections. If it is correct and
the problem persists, contact the
customer service of the manufacturer’s
service.
The computer is damaged
Contact the manufacturer’s service.
The connection between the
control board and the computer is
blocked
Contact the manufacturer’s service.
E02
The motor does not
operate
Incorrect supply voltage
Make sure the voltage is correct. If the
problem persists, contact the customer
service of the manufacturer’s service.
Incorrect connection of the motor
cable
Disconnect the cable and connect it again.
If the problem persists, contact
manufacturer’s service.
The controller is damaged
Contact the manufacturer’s service.
E03
The computer failed to
detect speed sensor
signal for 15 seconds
Sensor connection incorrect
Contact the manufacturer’s service.
Sensor plug connection incorrect
Verify plug connections. If it is correct and
the problem persists, contact
manufacturer’s service.
Sensor failure
Contact manufacturer’s service.
E04
Communication error
Incorrect connection or damage to
the wires.
Contact manufacturer’s service.
E05
Overload error
Motor failure
Make sure the motor has not burnt out. If
not, disconnect the treadmill from the
mains and reconnect it. If the problem
persists, contact manufacturer’s service.
Too low rated current in the
controller.
Replace the controller. Contact the
manufacturer’s service.
Current exceeds the rated value
Make sure the weight of the user does not
exceed the maximum value for the device.
E06
Explosion-Proof
Protection. Incorrect
power supply
Supply voltage too low
Connect the device to the correct voltage.
Short circuit
Contact manufacturer’s service.
Summary of Contents for Tekno
Page 57: ...57 RU 230 AC 1200 42 6 0o C 40o C 10o C 60o C 120 H C 0 8 14 3 EN 957 6 EN 957 6 2010 A1 2014...
Page 58: ...58 RU 230 2000...
Page 59: ...59 RU 13 230...
Page 60: ...60 RU...
Page 63: ...63 RU 1 2 M8 45 49 M8 15 46 3 15 03 M8 45 49 D8 57 M8 56 M8 25 48 49 49 46 46...
Page 64: ...64 RU 4 37...
Page 65: ...65 RU 3 5 7 5 3 6 8 90 C...
Page 66: ...66 RU 3 90 A 90 B 1 5 2 3 7 8...
Page 67: ...67 RU 1 15 15 30 15 2 3...
Page 68: ...68 RU 5 START STOP 10 3 12 3...
Page 71: ...71 RU E01 E02 E03 15 E04 E05...
Page 72: ...72 RU E06 Explosion Proof Protection E07 E08 EEPROM E09 E10 E11 270 E13 E14 160 ON OFF...
Page 73: ...73 RU 24 1 2 3 14 4 21 5 40 6 7 8 9 10 a b c 11 12 14...