OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
43
ZI-RWM84
Proceed a complete turn again. The display
shows 100 | Add.
Remove the calibration weigth (100g) form
the outer side of the rim an attach it on th
inner side of the rim in the same angular
position.
Proceed a completet turn again. After the
wheel has come to a complete standstill the
display shows C
AL
| End. Now the calibration
procedure is complete.
Press ALU key to save the calibration data
and complete the calibration.
Remove the calibration weight and balance
the wheel as described in the following
chapter.
Self-calibration should be carried out from time to time or if there are doubts about the
correctness of the measured results.
18.6.1
Calibration distance value A
NOTICE:
optional for models with automatic data entry.
Press Fn, A+und A- keys, to enter the
programm.
The display shows C
AL
|
P10.
Pull out the front gauge to a length of 10 cm.
Press the ALU key to confirm the setting.
The display shows C
AL
| I
NT
.
Guide the gauge up to the flange and retain it.
Press the ALU key to save the data and to
complete the calibration.