Commissioning & Operation

.

DO NOT SWITCH ON THE HEATER UNTIL IT IS FILLED WITH WATER    

   

Open the inlet control valve or tap to allow the tank to fill with water, the tank will be full 

when water begins to run continuously from the spout or tap.
Close the inlet control valve or tap and switch on the electrical supply, adjusting the temperature 
control to the required level.
The contents of the water vessel will be heated to the selected temperature.

NB. 

During the heating cycle expansion will take place and water will drip from the spout 

or tap. This  will cease when the operating temperature has been reached, (approx 9 
mins/+50°C for the 5L models, approx. 18 mins/+ 50°C for the 10L model).
Therefore always ensure that the spout outlet is positioned over the basin.
Hot water is drawn off by opening the inlet control valve or tap, this allows cold water to 

enter the storage vessel as the heated water is displaced and is flowing out. 

Safety Warning. 

Under no circumstances is the water heater to be used if suspected of being frozen.

If water ceases to flow switch off the electrical supply immediately at the isolating switch.
It is then recommended that a qualified Plumber/Electrician checks the unit.

Any water can be drained via the cold inlet connection whilst in the original location.
To remove the outer case, prise off the temperature selector switch and release the screw 
located beneath it.
Remove the four front cover securing screws at the top and bottom of the unit, the outer case 
can now be lifted off.

Maintenance.

Very little maintenance is required, however it is recommended that the replacement of spare 
parts is carried out by a relevant competent person ie. Plumber or Electrician for any more 
information please contact the Service Dept. 

ZIP HEATERS (UK) LTD 

TEL.0845 6 005 005.

Problem

Possible cause

Solution

NO WATER

MAINS WATER NOT TURNED 

ON

CHECK SUPPLY AND TURN ON

NO HOT WATER

OVER TEMPERATURE CUT 

OUT HAS OPERATED

REFER TO INSTRUCTIONS ON 

PAGE 10.

FAULTY THERMOSTAT

REPLACE THERMOSTAT

FAULTY ELEMENT

REPLACE ELEMENT

WATER IS TOO HOT

THERMOSTAT IS SET TOO 

HIGH

RESET THERMOSTAT

FAULTY THERMOSTAT

REPLACE THERMOSTAT

Summary of Contents for Tudor II P4/52

Page 1: ...Please read these instructions carefully before commencing installation of the water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way...

Page 2: ...re commencing installation of the Point of Use Water Heater Please leave these instructions with the end user after installation To ensure you have a copy of the latest instructions visit www zipheate...

Page 3: ...ater that occurs during the heating cycle to be safely discharged During the heating cycle drips will form and fall from the delivery spout or tap and these will cease when the cycle has been complete...

Page 4: ...ce its wiring and piping must not be modified in any way In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by...

Page 5: ...NO CIRCUMSTANCES SHOULD THE SPOUT OR OUTLET BE CONNECTED TO A TAP WHICH IS CAPABLE OF BEING CLOSED The Zip Tudor II and Contract II is intended for connection to mains supply only In any other case p...

Page 6: ...310x265 Minimum weight kg Empty 3 5 4 0 Maximum weight kg Full 8 5 14 0 Rated volume litres 5 10 Water connections BSP 1 2 Protection class IP24 All data quoted at nominal supply voltage For higher su...

Page 7: ...settable cut out CT0122 X 5a Thermal fuse CT0120 X 6 Neon light indicator CT0129 4 X X 7 Retaining nut CT0115 4 X X X 8 Front cover 5L CT0103 3 X 8 Front cover OB 5L CT0123 X 8 Front cover UB 5L CT012...

Page 8: ...solating valve should be installed in the water supply line to the heater A minimum clearance of 270mm is required underneath the overbasin heater units and above the underbasin units to allow for the...

Page 9: ...d Supply In Hot to Tap ZIP Approved Vented Tap Underbasin Installation In all underbasin installations the outlet must be connected to an open outlet type fitting approved by Zip heaters The diagram b...

Page 10: ...e wired with a 1 metre length of cable If in the lifetime of the unit the cable is damaged or a greater length of cable is required then to replace the supply cable refer to the following Cable instal...

Page 11: ...imply switching off the electrical supply to the unit for at least 2 minutes When power is restored the cut out will have reset However if the fault persists then the unit should be isolated from the...

Page 12: ...r no circumstances is the water heater to be used if suspected of being frozen If water ceases to flow switch off the electrical supply immediately at the isolating switch It is then recommended that...

Page 13: ...Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner...

Reviews: