Page 14 of 28
801314 v3.05 09.20 HT BC Commercial Instructions
Booster Installation
3.2
Installation Procedure
Site requirements
•
The appliance must only be installed in a frost-free area. Never expose the appliance to frost.
•
The appliance is designed for wall mounted installation and must to be installed with water connectors
facing upwards.
•
The appliance complies with protection class IP 25.
•
The 400mm braided hoses supplied with the Command Centre cannot be lengthened.
•
The 90° elbow hose ends should be fitted to the inlet and outlet connections on top of the Booster.
•
The hot water outlet hose must be thermally insulated with the insulation provided.
Tilt Forward
Lift UP
Release
Note
Note:
Remove the backing plate for wall mounting
3.3
To Remove / Install the appliance
1. Insert a flat head screwdriver all the way into the lock.
2. Gently angle the screwdriver upwards by approximately 10° as shown in the image below.
3. Pull the appliance forwards by approximately 15° as shown.
4. Carefully pull the appliance upwards to complete the removal process, taking care not to break the
lower clips
5. To install: place the appliance on the wall bracket and snap into position (see illustration below).
Take care not
to break the
lower clips when
removing or
installing the
Booster
!
Installation