Zip HydroTap G4 Installation And Operating Instructions Manual Download Page 1

801314 v3.05 09.20 HT BC Commercial Instructions 

Page 1 of 28

Zip HydroTap G4

Affix Model Number Label 

Here

 801314

Installation and Operating Instructions

®

BC Commercial

Summary of Contents for HydroTap G4

Page 1: ...801314 v3 05 09 20 HT BC Commercial Instructions Page 1 of 28 Zip HydroTap G4 Affix Model Number Label Here 801314 Installation and Operating Instructions BC Commercial...

Page 2: ...irectly compatible with the HydroTap G4 Command Centre The All In One Tap is a stand alone tap that may be used as an alternative to any of the above combinations The Mixer tap range is an additional...

Page 3: ...3 1 Product Description 13 3 2 Installation Procedure 14 3 3 To Remove Install the appliance 14 3 4 Braided Hose Connections 15 STEP 4 Mount the external filter softener if required Section 4 Command...

Page 4: ...appliance F Check the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the Command Centre has been ins...

Page 5: ...t to boil the water These units dispense boiling water factory set to 98 C and chilled water factory set to 5 9 C These units are NOT designed to be used for sanitary fixtures The Boiling water Comman...

Page 6: ...visible position for connection Venting Sometimes steam and or condensed droplets may discharge through a vent outlet at the tap If the tap is not installed using the Font pedestal ensure the tap body...

Page 7: ...ides and 200mm above to allow for air circulation Additional means of ventilation is critical if the vent kit as supplied cannot be fitted 6 Flush water supply lines before any plumbing connections ar...

Page 8: ...or vent louvre 1 x Front vent grill 1 X HydroTap Booster Heater hoses Supplied with 240 175 models 1 x Flow Restrictor and Tee piece for Mixer taps and select models 1 x Mixer Tap for 4 In 1 and selec...

Page 9: ...oost Rating kW Unit Dimensions W x D x H mm with air duct Dry Weight kg Boiling Chilled BC160 125 160 125 no 1x10A 2 1 450 x 470 x 335 23 BC160 175 160 175 no 1x10A 2 2 450 x 470 x 335 23 BC240 175 24...

Page 10: ...and the stop cock will not be obstructed when the Command Centre is installed For the mains pressure All in One tap an external hot and cold water supply will be required If an external filtration or...

Page 11: ...ducts the following tools will be required Jigsaw and 12mm Drill Keyhole or Wall Board saw Section 2 Ventilation Cool Air IN via cabinet floor front vent grille Warm Air OUT via kickboard louvre Reco...

Page 12: ...0 00 B C 12 00 45 00 284 285 00 1 2 0 0 60 00 WALL OR DOOR CUT OUT 228 1 2 98 AIR OUTLET CUT OUT Min 450mm For positioning of cut out C use the template marked on the cardboard carton The following in...

Page 13: ...heating of water before it enters the Zip HydroTap G4 boiling tank The Booster is supplied as standard equipment with all 240 cup models However it may be later installed as an accessory for the 160...

Page 14: ...ctions on top of the Booster The hot water outlet hose must be thermally insulated with the insulation provided Tilt Forward Lift UP Release Note Note Remove the backing plate for wall mounting 3 3 To...

Page 15: ...Bypass Out fitting on the Zip HydroTap to the water inlet of the booster unit Marked Blue and from the outlet of the booster unit Marked Red to the Bypass IN fitting on the Zip HydroTap Command Centr...

Page 16: ...the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 3 Moisten the O rings with water align the front cartridge label to the left and push the new cartridge...

Page 17: ...Do not overtighten John Guest fittings Insertion and removal Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted 1 Use a sharp knife to ensure th...

Page 18: ...e length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to have a nee...

Page 19: ...is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant...

Page 20: ...rd lengths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the Hy gradient to the Hy droTap to allow all droTap to allow all water...

Page 21: ...tube lengths are matched to the pump performance and therefore CANNOT be lengthened Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap...

Page 22: ...ANNOT be lengthened Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the...

Page 23: ...the Boiling calibration mode NOTE For any subsequent filter changes or any operational procedures please refer to the HydroTap user guide located inside the filter housing access door A new filter ca...

Page 24: ...ooster Press the calibration button and the system will commence the Boiling calibration procedure This will take approx 5 6 minutes Upon completion a Booster reminder screen will appear and allow you...

Page 25: ...ight must be shaded from the HydroTap during the calibration This can be achieved by closing any nearby curtains blinds or by shielding the HydroTap with a dark cloth Safety sensor Pull both levers fo...

Page 26: ...l Zip Service Condenser sensor Open Internal fault Check ventilation Call Zip service Heater fuse driver fault Internal fault Call Zip Service Heater driver fault No hot water Call Zip Service Compres...

Page 27: ...BC Commercial Instructions Page 27 of 28 End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for col...

Page 28: ...TAP 1800 947 827 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further pate...

Reviews: