Zip HydroTap All-In-One 89944 Installation And Operating Instructions Manual Download Page 20

Page 20 of 20 

 HydroTap Installation and Operating Instructions - 89944 - July 2011 v1.01

 Warranty

The standard cup referred to in this publication is 167 ml (6 fl oz). 
The standard glass is 200 ml (7 fl oz). 
The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. 
Zip products described in this publication are manufactured under one or more of the following 
patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, 
and US5099825.  Other patents are in force and patent applications are pending. 

As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. 
Images in this booklet have been modified and may not be true representations of the finished goods.

Warranty table effective from 1st January 2009.

Full warranty details may be found on the  website

Normal Warranty

Extended warranty

12 Months

24 Months

36 Months

48 Months

60 Months

Domestic 

HydroTap

Parts & Labour

Parts & Labour

Replacement 
@25% rrp

Replacement 
@33% rrp

Replacement 
@50% rrp

HydroBoil

Parts & Labour

Parts & Labour

Replacement 
@25% rrp

Replacement 
@33% rrp

Replacement 
@50% rrp

AutoBoil

Parts & Labour

Parts Only

Replacement 
@25% rrp

Commercial 

HydroTap

Parts & Labour

Parts & Labour

All Other

Parts & Labour

Head Office

Zip Heaters (Aust) Pty. Ltd.
ABN: 46 000 578 727
67 Allingham Street
Condell Park NSW 2200 
Postal: Locked Bag 80
Bankstown 1885 Australia

Website: www.zipheaters.com
Facsimile: (02) 9796 3858
Telephone: (02) 9796 3100
Free Call: 1 800 638 633

Registering Your Purchase

Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary 
to service the appliance under terms of the Zip warranty. To register your installation go to www.zipheaters.com and look 
under the heading “Register your purchase/Warranty information”, or forward the completed product registration form 
(enclosed) to your nearest Zip head office.

NOTE:

 Extended warranty and Pro-Rata warranty will only be available on products which have been registered with Zip 

head office

Summary of Contents for HydroTap All-In-One 89944

Page 1: ...e 1 of 20 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the...

Page 2: ...on 20 Hydrotap All In One series are able to supply Boiling and Chilled water as well as Hot and Cold water all from the same tap The A series have their Boiling Chilled Hot and Cold outlets connected...

Page 3: ...ded The system will operate satisfactorily only if the recommended air gaps are provided these are 65mm min rear clearance and 50mm side clearance An air vent is provided with each unit for high usage...

Page 4: ...ollow the instructions on page 15 16 or contact your Service Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use...

Page 5: ...t tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circums...

Page 6: ...y to tighten the hose firmly by hand Excess force may damage the O rings Check these joints for leaks during initial operation Measure and trim the blue silicon tube and connect it to the chilled wate...

Page 7: ...Orient the USB plug carefully and connect do not force the plug Once connected fix the cable to the wall ensure it is away from any possible water splashes and is off the floor Fasten the tap body to...

Page 8: ...it at that temperature for a short stabilization period Once stabilized the element will cycle ON bring the water to boiling point and hold it there for a short period The unit now carries out a self...

Page 9: ...ing the handle up will decrease the flow rate and lowering the handle will increase the flow rate Lift the handle all the way up to turn the tap off When the handle is moved to the left the temperatur...

Page 10: ...TO TAP 240V GPO NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGME...

Page 11: ...65 220 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM BOILING WATER TANK IN HYDRO...

Page 12: ...ROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BH1 B H 2 B H 3 NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM...

Page 13: ...ALL IN ONE TAP VENTED VERSION MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED 220 65...

Page 14: ...ing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of this document Boiling Water Lever Depressing...

Page 15: ...ent cartridge and write today s date where shown on the label 8 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs w...

Page 16: ...o reset the Filter Change display after a filter has reached the end of its life refer to Replace Filter Instructions section of this document Press either Mode or Mode button until Litres Filtered is...

Page 17: ...vice mode To access the service mode Press both the Adjust and Adjust buttons simultaneously and hold for several seconds until the screen displays the HOT and COLD temperatures Press the Mode button...

Page 18: ...k 3 three times rapidly the LED s will scroll from left to right 3 three times This operation confirms the activation 4 This isolates the boiling tap only The LCD shows isolation mode is active 5 To d...

Page 19: ...e Child safety lock see P10 No water flow from mixer tap Faulty non return valve Check and Replace faulty non return valves 3 11 Faulty restrictaflow valve Clean and reset restrictaflow valve item 20...

Page 20: ...Months Domestic HydroTap Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp HydroBoil Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp...