Zip HydroTap All-In-One 89944 Installation And Operating Instructions Manual Download Page 15

HydroTap Installation and Operating Instructions  

                              Page 15 of 20

The Zip HydroTap notifies when filter replacement is due. The default setting is 6000 Ltrs, 
but this can be set in increments of 1000Ltr from 1000Ltr to 10000Ltrs. When a filter 
change is due, the Change Filter light will flash white once a minute and remain so until 
reset. A filter status light is located between the Red and Blue Lights on the tap head 
assembly. 

Depending on local water quality conditions and usage, the filter may require changing 
anywhere from 1000 Ltrs to 10000 Ltrs. You may also need to replace the filter if you notice 
unpleasant odours or tastes.

Some water may drip from the filter head (socket) during replacement. Keep a bucket and 
towel handy to catch drips and mop up any spills.

To change the Filter:

1.  Scroll through the screen menu to “Filter Flush Off” this isolates the water supply.

2.   Open the door on the left

3.  Relieve system pressure via the filter flush stop cock, a quick open and close will do. 

Use the bucket to catch the discharge.

4.  Grasp filter cartridge and twist right to left one quarter turn until it stops.

5.  Ease cartridge downwards to detach it from the filter head (socket).

6.  Do not tilt the cartridge as dirty water may spill from it if tilted.

7.  Unpack replacement cartridge and write today’s date where shown on the label. 

8.  Avoid touching the filter “O” rings and filter opening as this may cause bacterial 

contamination of the cartridge.

9.  Align cartridge tabs with the slots on the under-side of the filter head.

10. Slide cartridge upward into head and rotate left to right until it stops.

11. Locate the filter flush hose situated behind the filter cartridge and run to a container 

ready for flushing. Open the flush hose tap lever. On the control panel press Adjust 

>

, this will start the water flushing the cartridge. Allow at least 7.5 Ltrs of water to run 
through to activate the filter and then press Adjust 

>

 to stop the flow.

12. Isolate the filter flush stop cock and re-fit behind the filter cartridge.

13. Wipe up any spills and dispose of spent filter cartridge and packaging thoughtfully.

14. Scroll through the menu to “Litres Filtered”, press Adjust 

>

 to reset litre counter. Press 

Adjust 

>

 and it asks “are you sure”. Press Adjust 

>

 again to lock in the command. 

15. Scroll through the menu to “Filter Used (Days)”, press Adjust 

>

 to reset the timer. Press 

Adjust 

>

 and it asks “are you sure”. Press Adjust 

>

 again to lock in the command. 

After approx 10 seconds it will default to the selected mode.

16. Close the door to secure the appliance. 

 Replacing the Filter 

Setting the Energy Saver Timer 

Mode Plus Button

Mode Minus Button

Plus Adjust Button

Minus Adjust Button

Note:

Mode buttons  
change the 
screen options

Adjust buttons 
select the 
screen options

Summary of Contents for HydroTap All-In-One 89944

Page 1: ...e 1 of 20 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the...

Page 2: ...on 20 Hydrotap All In One series are able to supply Boiling and Chilled water as well as Hot and Cold water all from the same tap The A series have their Boiling Chilled Hot and Cold outlets connected...

Page 3: ...ded The system will operate satisfactorily only if the recommended air gaps are provided these are 65mm min rear clearance and 50mm side clearance An air vent is provided with each unit for high usage...

Page 4: ...ollow the instructions on page 15 16 or contact your Service Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use...

Page 5: ...t tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circums...

Page 6: ...y to tighten the hose firmly by hand Excess force may damage the O rings Check these joints for leaks during initial operation Measure and trim the blue silicon tube and connect it to the chilled wate...

Page 7: ...Orient the USB plug carefully and connect do not force the plug Once connected fix the cable to the wall ensure it is away from any possible water splashes and is off the floor Fasten the tap body to...

Page 8: ...it at that temperature for a short stabilization period Once stabilized the element will cycle ON bring the water to boiling point and hold it there for a short period The unit now carries out a self...

Page 9: ...ing the handle up will decrease the flow rate and lowering the handle will increase the flow rate Lift the handle all the way up to turn the tap off When the handle is moved to the left the temperatur...

Page 10: ...TO TAP 240V GPO NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGME...

Page 11: ...65 220 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM BOILING WATER TANK IN HYDRO...

Page 12: ...ROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BH1 B H 2 B H 3 NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM...

Page 13: ...ALL IN ONE TAP VENTED VERSION MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED 220 65...

Page 14: ...ing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of this document Boiling Water Lever Depressing...

Page 15: ...ent cartridge and write today s date where shown on the label 8 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs w...

Page 16: ...o reset the Filter Change display after a filter has reached the end of its life refer to Replace Filter Instructions section of this document Press either Mode or Mode button until Litres Filtered is...

Page 17: ...vice mode To access the service mode Press both the Adjust and Adjust buttons simultaneously and hold for several seconds until the screen displays the HOT and COLD temperatures Press the Mode button...

Page 18: ...k 3 three times rapidly the LED s will scroll from left to right 3 three times This operation confirms the activation 4 This isolates the boiling tap only The LCD shows isolation mode is active 5 To d...

Page 19: ...e Child safety lock see P10 No water flow from mixer tap Faulty non return valve Check and Replace faulty non return valves 3 11 Faulty restrictaflow valve Clean and reset restrictaflow valve item 20...

Page 20: ...Months Domestic HydroTap Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp HydroBoil Parts Labour Parts Labour Replacement 25 rrp Replacement 33 rrp Replacement 50 rrp...