Page 8 of 20
HydroTap Installation and Operating Instructions
Step E- Testing and commissioning
Model Selection Procedure
This procedure applies to HydroTap products with date of manufacture (DOM)
after and including 30th July 2012 or with a serial number starting with
20120730xxxxx.
The procedure covers model selection and cold temperature set point
adjustment.
1. Turn on the unit, the screen will display the general information of the
product for approximately 2 seconds. See Fig.1 alongside as an example
for HydroTap BC range. Product range descriptions could be one of the
following:
BO1.30E11O
CP1.30E11O
BF1.30E11O
BC1.30E110
BA1.30E11O
CO1.30E11O
BC CORR3
BF CORR3
2. The screen will then display “To Select Model Press ADJUST->“ as shown
in Fig.2. Press ADJUST ^ or button to check the model number.
3. The screen will now display “<-Scroll Exit->“ on the first line and the
model description on the second line as shown in Fig.3. The factory default
model description displayed on the screen should match the product model
description on your product labels. If the correct model description is
displayed, select “Exit” by pressing ADJUST ^ or to confirm selection and
exit model description selection setting.
If the model description displayed is incorrect, select the “Scroll” option by
pressing MENU ^ or button to scroll through the model discription until
the correct model description is displayed then select “Exit” by pressing
ADJUST ^ or
>
to confirm selection and exit model description selection
setting.
4. The model selection is now complete. The “Start Filt Flush“ will be
displayed. To continue with the filter flush and calibration refer to the
Testing and Commissioning within the main instruction.
Filter Flush Mode
The display screen will show which model you have.
Have a bucket or similar container (not supplied) at the ready to hold a quantity
of water that is ejected while the Filter Flush Mode is in operation. Open the
filter access door on the front of the HydroTap and the filter cartridge will be
exposed. Located to the rear RHS of the cartridge is a fixed flush line, approx
600mm long and the flush line stop cock. Place the free end of the flush line
into the bucket or container (not supplied).
Turn “ON” both water and electricity supplies and open the flush line stop
cock. The display will show Filter Flush Mode. To activate press adjust
<
Run at least 7.5 Litres of water through to activate the filter membrane.
Press the adjust
<
button again to stop the Filter Flush Mode.
Turn OFF the
Filter Flush stop cock and re-locate the tube and stop cock in the filter
compartment.
Turning OFF the Filter Flush Mode puts the HydroTap into
Installation
procedure
continued
Use these buttons to
scroll through the menu
Use these buttons to
activate and de-activate
the program selected
Zip Industries
HTAP BC 1.30E11O
To Select Model
Press ADJUST ->
<- Scroll Exit->
BC160/125+
Start Filt Flush
>Press Adjust ^
Fig.1
Fig.2
Fig.3
Fig.4
Press ADJUST ^ or to exit
>
Press MENU ^ or
to scroll through the
model numbers.
<
<
<