HydroTap Installation and Operating Instructions
Page 7 of 20
the USB plug carefully and connect, do not force the plug. Once connected, fix
the cable to the wall, ensure it is away from any possible water splashes and
is off the floor.
Model: NON Vented.
Connect the two braided hoses to the Hot and Cold water supply, as shown in
pages 10-11.
Measure and trim the red marked tube and connect it to the hot water outlet,
on the top of the undersink unit. Use spring clamps provided to secure the
hose.
Measure and trim the unmarked tube and connect it to the vent outlet on the
top of the undersink unit. Use spring clamps provided to secure the hose.
NOTE:
Both tubes must have a continuous fall back to the undersink unit.
Connect the tap USB connector to the USB port on the undersink unit. Orient
the USB plug carefully and connect, do not force the plug. Once connected, fix
the cable to the wall, ensure it is away from any possible water splashes and
is off the floor. Fasten the tap body to the sink using the bolt & plate system
provided.
The following instruction is CRITICAL:
Adjust both cupboard door hinges and attach the supplied rubber door buffers
to the doors to create a 4 mm air-gap between the doors and the cupboard.
This is the minimum ventilation requirement for low usage installations.
Proper air circulation must be provided for all Boiling and Chilled models. The
system will operate correctly only if the recommended air gaps are achieved
during installation. A ventilation hole measuring 100mm must be cut into the
top half of the cupboard door to accommodate the air vent provided. Make
sure that the undersink unit ventilation grilles are not obstructed in any way.
Cupboard ventilation for Boiling only models is recommended.
Step D - Connecting the water supply
To prevent sediment from entering the HydroTap at connection, flush water
through the supply line thoroughly before connection to the HydroTap. Open
the access door and check that the filter is in place and secure. Connect the
water supply to the undersink unit using the attached flexible hose .Turn ON
water and check for leaks. If no leaks are evident turn the power ON.
Installation procedure
continued
Vent line
Chilled line
Hot line
HydroTap connections for
Undersink unit