6. Measure & split Armaflex to fit and wrap hoses
to tap.
7. Tightly wrap split Armaflex for condensation
control.
8. Wrap but expose the stop valves up to the Tap,
so adjustment can be made if necessary. Mark
the stop valves C/S/A for each water type.
9. Enclose end at chiller box with wrap and tape.