Zip Hydroboil Electronic - Installation & Operating Instructions - 86584 - July 2008

Page 11 of 16

In 2 Hour Sleep Mode, if there has been no water drawn through the tap or no touches of the capacitive switch sensors
for two hours, the temperature of the water in the tank will be allowed to drop to and be maintained at 65ºC. (The time
taken for the water temperature to drop to 65ºC can be as much as 12 hours depending on ambient conditions and other
external factors).

In 4 Hour Sleep Mode, if there has been no water drawn through the tap or no touches of the capacitive switch sensors
for four hours, the temperature of the water in the tank will be allowed to drop to and be maintained at 65ºC.

As soon as water is drawn through the tap, or there is a touch on the capacitive switch sensors, the Hydroboil returns to
full power mode.

In Low Light Mode, as soon as the ambient light (in the room where the Hydroboil is installed ) drops below 100lux, the
unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be maintained at
65ºC. As soon as the ambient light rises above 100lux, the Hydroboil returns to full power mode.

A normal office has an ambient light level of 200-300lux.

The Default configuration for the Hydroboil is as follows.

Default settings

TEMPERATURE SETPOINT:

98ºC

FILTER TIMER:

OFF

SLEEP MODE:

OFF

LOW LIGHT MODE:

OFF

SUN ON TIME 1:

--:--

SUN OFF TIME 1: --:--

SUN ON TIME 2:

--:--

SUN OFF TIME 2: --:--

MON ON TIME 1:

08:00

MON OFF TIME 1: --:--

MON ON TIME 2:

--:--

MON OFF TIME 2: --:--

TUE ON TIME 1:

--:--

TUE OFF TIME 1:

--:--

TUE ON TIME 2:

--:--

TUE OFF TIME 2:

--:--

WED ON TIME 1:

--:--

WED OFF TIME 1: --:--

WED ON TIME 2:

--:--

WED OFF TIME 2: --:--

THU ON TIME 1:

--:--

THU OFF TIME 1:

--:--

THU ON TIME 2:

--:--

THU OFF TIME 2:

--:--

FRI ON TIME 1:

--:--

FRI OFF TIME 1:

--:--

FRI ON TIME 2:

--:--

FRI OFF TIME 2:

--:--

SAT ON TIME 1:

--:--

SAT OFF TIME 1:

--:--

SAT ON TIME 2:

--:--

SAT OFF TIME 2:

--:--

Setting operational modes

The Hydroboil has 2 modes of operation:

1).Normal operation mode                 2). Configuration mode

Note:

The BOILING WATER symbol is not displayed until the water reaches

temperature.

In Normal operation mode the LCD will display as follows:

Normal display

d

a

b

d

e

g

g

f

c

b

dp

dp

a

b

c

f

g

f

e

d

c

b

a

Normal mode

[email protected]

www.chilli-b.co.za | 012 809 4026

[email protected]

www.chilli-b.co.za | 012 809 4026

Summary of Contents for Hydroboil 203062

Page 1: ...Hydroboil 3 Litre White 203061 Zip Hydroboil 3 Litre Stainless Steel 205062 Zip Hydroboil 5 Litre White 205061 Zip Hydroboil 5 Litre Stainless Steel 207062 Zip Hydroboil 7 5 Litre White 207061 Zip Hy...

Page 2: ...Page 2 of 16 Zip Hydroboil Electronic Installation Operating Instructions 86584 July 2008 retha chilli b co za www chilli b co za 012 809 4026 antonius chilli b co za www chilli b co za 012 809 4026...

Page 3: ...stallation Requirements 4 Installation Procedures 5 6 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Wal...

Page 4: ...bient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard does not offer the same protection to the connecting pipework and fit...

Page 5: ...he tap will drain on to a draining board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger v...

Page 6: ...he heater rear using a visible tundish see diag at left c Electrical For concealed electrical connection connect a power cable through the rear access opening of the heater to the terminal block withi...

Page 7: ...ct needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical...

Page 8: ...iance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an appliance tester or continuity tester of accuracy Class 5 or b...

Page 9: ...indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Zip Hydroboil is fitted with a safety two way cool touch safet...

Page 10: ...an have 2 ON OFF times per day If the user selects either of the energy saver modes see below ON OFF mode cannot be used The user is not able to access this part of the configuration The real time clo...

Page 11: ...of the stored water to drop to and be maintained at 65 C As soon as the ambient light rises above 100lux the Hydroboil returns to full power mode A normal office has an ambient light level of 200 300l...

Page 12: ...HE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CSS2 or CSS3 To step to the next configuration parameter press CSS1 SET FILTER EXPIRATION TIME To return to...

Page 13: ...sensor is configured as off the user will be able to use ON OFF mode SUN ON TIME 1 To return to Normal Mode press CSS4 To increment the hour for SUN ON TIME 1 press either CSS2 or CSS3 To step to the...

Page 14: ...732 Tap Handle Kit 15 90745 Outlet Nozzle Kit Grey 16 90503 Strap and Key Kit 3Litre Hydroboil 16 90504 Strap and Key Kit 5L 7 5Litre Hydroboil 17 90505 Tap Nut Kit 18 90509 Tap Body Kit 19 90485 Elem...

Page 15: ...droboil Electronic Installation Operating Instructions 86584 July 2008 Page 15 of 16 Spare Parts retha chilli b co za www chilli b co za 012 809 4026 antonius chilli b co za www chilli b co za 012 809...

Page 16: ...water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excl...

Reviews: