background image

Page 4 of 16

Zip Hydroboil Electronic - Installation & Operating Instructions - 86584 - July 2008

Read These Warnings First

Please read all installation requirements, installation procedures and precautions before
installing any Zip Hydroboil instant boiling water heater.

Never attempt to install any Zip Hydroboil instant boiling water heater without reading all of
the applicable instructions.

In some hard water areas where mineral scale accumulation in the boiling chamber of the
Zip Hydroboil may become a problem, consideration should be given to the maintenance
required. A suitable form of water treatment may be necessary.

All plumbing connections must be made in accordance with local regulations.

The Zip Hydroboil instant boiling water heater is not intended for use by young children or
infirm people without supervision.

Young children should be prevented from having access to ensure that they are not able to
use or play with the heater.

If the installation site is located more than 1000 metres above sea level, the installer should
contact a Zip authorised agent for high altitude settings.

This appliance must be earthed. If the power supply cord is damaged it must be replaced
by a Zip authorised agent or a qualified electrician.

Do not remove the cover of the heater under any circumstances without first isolating the
heater from the power supply.

Do not use strong, corrosive or abrasive cleaners to clean the case of the heater.

Frost protection: If this heater is located where ambient air temperature could fall below 5ºC
when the heater is not in use, do not turn off the appliance electrically. This safeguard does
not offer the same protection to the connecting pipework and fittings.

The ambient temperatures this unit must operate within is 5ºC - 50ºC.

This heater is intended only for indoor use and should never be installed outdoors or be
exposed to the elements of nature.

This unit must not be positioned in an area that may be cleaned by a water jet. This unit
must not be cleaned by a water jet.

Before installing, ensure that the following are available:

a)

Sufficient space to position the heater so there is at least 150 mm 

clearance above the heater for service access, 65 mm to its left and 

20 mm to its right – the tap outlet usually should be positioned at least 

200 mm above a draining board or drip tray.

b)

Standard local requirement power cable positioned as shown on the paper mounting

template for connection from the rear of the heater to the terminal block within the heater,
this will require an isolating switch fitted in the fixed wiring and attached to a secure
surface. This switch must provide all pole disconnection and a contact seperation of at least
3mm installed in accordance with the wiring rules. Alternatively a standard 220-240V, 10
amp general purpose outlet, within 1500 mm of the Hydroboil Unit.

NOTE: When installed with a plug and cord the plug must be accessible

c)

Cold water supply with a minimum working pressure of 100 kpa and a maximum

working pressure of 700 kpa connected via an isolation valve.

Installation Requirements

[email protected]

www.chilli-b.co.za | 012 809 4026

[email protected]

www.chilli-b.co.za | 012 809 4026

Summary of Contents for Hydroboil 203062

Page 1: ...Hydroboil 3 Litre White 203061 Zip Hydroboil 3 Litre Stainless Steel 205062 Zip Hydroboil 5 Litre White 205061 Zip Hydroboil 5 Litre Stainless Steel 207062 Zip Hydroboil 7 5 Litre White 207061 Zip Hy...

Page 2: ...Page 2 of 16 Zip Hydroboil Electronic Installation Operating Instructions 86584 July 2008 retha chilli b co za www chilli b co za 012 809 4026 antonius chilli b co za www chilli b co za 012 809 4026...

Page 3: ...stallation Requirements 4 Installation Procedures 5 6 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Wal...

Page 4: ...bient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard does not offer the same protection to the connecting pipework and fit...

Page 5: ...he tap will drain on to a draining board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger v...

Page 6: ...he heater rear using a visible tundish see diag at left c Electrical For concealed electrical connection connect a power cable through the rear access opening of the heater to the terminal block withi...

Page 7: ...ct needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical...

Page 8: ...iance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an appliance tester or continuity tester of accuracy Class 5 or b...

Page 9: ...indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Zip Hydroboil is fitted with a safety two way cool touch safet...

Page 10: ...an have 2 ON OFF times per day If the user selects either of the energy saver modes see below ON OFF mode cannot be used The user is not able to access this part of the configuration The real time clo...

Page 11: ...of the stored water to drop to and be maintained at 65 C As soon as the ambient light rises above 100lux the Hydroboil returns to full power mode A normal office has an ambient light level of 200 300l...

Page 12: ...HE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CSS2 or CSS3 To step to the next configuration parameter press CSS1 SET FILTER EXPIRATION TIME To return to...

Page 13: ...sensor is configured as off the user will be able to use ON OFF mode SUN ON TIME 1 To return to Normal Mode press CSS4 To increment the hour for SUN ON TIME 1 press either CSS2 or CSS3 To step to the...

Page 14: ...732 Tap Handle Kit 15 90745 Outlet Nozzle Kit Grey 16 90503 Strap and Key Kit 3Litre Hydroboil 16 90504 Strap and Key Kit 5L 7 5Litre Hydroboil 17 90505 Tap Nut Kit 18 90509 Tap Body Kit 19 90485 Elem...

Page 15: ...droboil Electronic Installation Operating Instructions 86584 July 2008 Page 15 of 16 Spare Parts retha chilli b co za www chilli b co za 012 809 4026 antonius chilli b co za www chilli b co za 012 809...

Page 16: ...water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excl...

Reviews: