Arc and Cube HydroTap

®

G4

Flashing quickly - warning light

When the indicator light flashes fast and continuous, a system fault has 

occurred. Check for details on the faults screen (see page 9). If unable to 

rectify, call a qualified service agent.

Filter lights

All three tap lights will flash every 10 seconds, indicating a filter change

is required.

Reset the filter light

 

see page 11.

To dispense chilled water 

Rotating the control when the indicator light is illuminated blue allows the 

dispensing of chilled water.

(If illuminated white, touch the SELECT button until the indicator light 

illuminates blue). 

To dispense sparkling water 

Rotating the control when the indicator light is illuminated white allows the 

dispensing of sparkling water.

(If illuminated blue, touch the SELECT button until the indicator light 

illuminates white). 

Note 

The

 

SAFETY button has no function other than visual illumination on 

the chilled and sparkling configuration.

Celsius HydroTap

®

G4

Celsius functionality

The Celsius range use a rotary control to 

dispense water .

Turning the rotary control in either direction 

allows the dispensing of chilled or sparkling 

water. For your convenience, the rotary 

control is spring loaded, so when released, 

will return automatically close the tap.

Tap lights

Warning light

Blue or white CHILLED water 

light -

continually illuminated

This indicates that the chilled water is ready.

Warning light

Rotary 

control

Indicator 

light

Summary of Contents for Elite HydroTap G4 range

Page 1: ...801981UK Commercial Chilled sparkling User manual Sept 2016 v3 02 Page 1 of 20 ZIP HydroTap G4 User Manual Affix model number label here 801981UK...

Page 2: ...ispense chilled and sparkling water When operating the tap ensure the touch surface is dry as moisture may interfere with the sensor touch control Tap lights Blue CHILLED water light Continually illum...

Page 3: ...uses lever switch controls to operate the tap Lever controls can be pushed back to dispense water manually or pulled forward to dispense water for a fixed time period see page 17 Once pulled forward...

Page 4: ...librate The Arc Cube control may be rotated in a forward or reverse direction to dispense chilled or sparkling water The rotary control is spring loaded in the forward direction and when released will...

Page 5: ...r light illuminates blue To dispense sparkling water Rotating the control when the indicator light is illuminated white allows the dispensing of sparkling water If illuminated blue touch the SELECT bu...

Page 6: ...shing slowly The warning light will flash slowly 1 second on and 3 seconds off whenever the water is not at the temperature set point The tap may still be operated but the water may not be at the desi...

Page 7: ...in status window Status Information Notes System Fault Product has one or more system faults Refer to section B System info Change filter Internal filter needs to be replaced Refer to section C Insta...

Page 8: ...nd Reset B Installation Filter flush Filter reset CO2 Purge Lux sensor calibration Start Stop Internal External Calibration options Enable Disable C Service Password protected D Security Enable passwo...

Page 9: ...ult Log to check the fault information Press button for the previous menu or press HOME button to return to the home screen Press Filter Log to check the filter resets Press button for the previous me...

Page 10: ...0mm long and the flush line stop cock Place the free end of the flush line into the bucket or container not supplied Press MENU button for main menu Press the Install button Turn the stop cock on Pres...

Page 11: ...ration button The lights on the tap head will flash to confirm calibration Note Correct operation of the Lux sensor can be verified by selecting Lux Sensor OFF When the room is subsequently darkened b...

Page 12: ...rotect against users changing the preferred system settings To set a password Press the MENU button for main menu Press the Security button Press Enable Password Enter a 4 digit password Press Enter T...

Page 13: ...nd press Enter Press the Date Time button Choose 12 HOUR mode or 24 HOUR mode by pressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Press N...

Page 14: ...um of 10000 litres Factory set at 6000 litres To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 17 Filter maintenance...

Page 15: ...after a 2hr period of inactivity The chilled water will be ON or OFF Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes b...

Page 16: ...U button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the On Off Modes Menu button Select Individual Set if you wish to alloc...

Page 17: ...G4 notifies when filter replacement is due If you notice one of the following you will need to change the filter The white change filter light will flash and remain so until reset The filter percentag...

Page 18: ...until the cartridge comes to complete stop and is locked into position with the front label facing forward Initiate the filter flush programme by scrolling through the menu screen see page 10 When co...

Page 19: ...the cylinder joint Any CO2 released will be cold Install the cylinder in an upright position use the hook and loop securing strap Turn the regulator on turn regulator knob anti clockwise to end stop...

Page 20: ...Sleep mode is active There are 4 sleep mode options which display this icon on the home screen See tap sections for details Filter use This icon displays the filter usage remaining from 100 new filter...

Reviews: