Installation instructions & user manual
804544UK V2.03 Oct 2018 - Zip Econoboil
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
Installation instructions
Electrical
Exposed electrical connection
Connect via a 1.5mm
2
3 core cable.
Connect the 3 core cable to the terminal block, via the
strain relief bush. See adjacent diagram.
Tighten the strain relief bush, to secure the cable.
Concealed electrical connection
Connect the concealed power cable through the rear access
opening to the terminal block. See adjacent diagram.
•
Do not turn the power ON until the Econoboil can
dispense water from the tap outlet.
•
Verify the earth continuity (see page 9).
!
!
Strain relief bush
Terminal block
Rear access
Step 4 - Assembly
• Without the cover on, turn the water on to check for any leaks. These should become apparent within a short
period of time. If all is dry then isolate water and replace cover. If there are any leaks repair as necessary.
• With the cover on, fit the red escutcheon over the outlet tube, secure with the locknut and apply PTFE tape to the
threaded portion of the outlet tube.
• Screw the tap assembly clockwise onto the outlet tube until it touches the escutcheon locknut. Continue to turn the
tap until the handle is fully vertical. Tighten the locknut against the tap with spanner provided (see page 9) leaving
the tap in a vertical position.
Thermostat
Heating
El
ement
N E A
2(Blu)
1(Red)
Overload
1(Red)
2(Blu)
Bl
k
Re
d
Re
d
Bl
k
Terminal
Block
Br
n
Bl
k
2
Grn/
Yel
Heating
Indicator
Ma
in
s
inpu
t
Electrical Wiring diagram