Instructions. V1.01
Page 9
JUNE / 2013
BROWN
BLUE
GREEN/YELLOW
RED
BLACK
HEATING ELEMENT
THERMOSTAT
NEON
INDICATOR BULB
EARTH
Supply through a
Fused doublepole
switch or fused
spur.
Tudor II and C3/50 models.
OVER TEMPERATURE
SAFETY CUT OUT
Electrical Installation.
WARNING:
SWITCH OFF THE MAINS ELECTRICAL SUPPLY BEFORE CARRYING OUT
ANY WORK INVOLVING A LIVE CIRCUIT. 230v AC SUPPLY ONLY, THIS APPLIANCE MUST BE
EARTHED.
Before starting installation the
WARNINGS
(page 3) and
CAUTIONS
(page 4) should be
read and fully understood.
It is recommended that the electrical installation is carried out by a qualified electrician.
fig.4
NB. Tudor II .
The Tudor models all come pre-wired with a 1 metre length of cable.
If in the lifetime of the unit the cable is damaged or a greater length of cable is required then
to replace the supply cable, refer to the following ‘Cable installation/replacement’
instructions.
Cable installation/replacement
( Tudor II and Contract II )
.
First remove the temperature adjustment selector switch and release the screw located
beneath.
Unscrew the four cover screws-two on the top and two on the bottom of the unit, this will
then allow the outer cover to be removed.
The supply cable should have a nominal cross section of not less than 1.5mm².
The supply cable enters the casing through a cable clamp located in the rear casing cover
Make the connections in the terminal block provided as indicated in (fig.4), then after ensuring
that the cable is firmly clamped, replace the front casing, cover and selector switch.