3.3 Electrical
Warning: Do not turn on the power until instructed. Water
must first be available from the tap outlet to prevent damage.
All wiring must be performed by a qualified electrician.
For concealed electrical connections, connect a power cable from the
rear of the heater to the terminal block within the heater as shown,
refer to diagrams Fig.1 and Fig.2.
For surface mount installations run the power cable through the cable
entry gland at the bottom of the unit to the terminal block within the
heater. Ensure the cable is firmly secured.
Thread Tape
2. Ensure suffi
cient thread tape is applied
to the thread.
1. Fit the cover to the unit and fi x with screws
top and bottom.
3. Turn the tap fully clockwise onto the outlet
tube until it touches the lock nut and is in an
upright position.
4. Use the spanner supplied to tighten the
lock nut anti-clockwise.
Lock nut
Step 4 – Installing Tap
Neutral
Earth
Live
Electrical connection for units
with 1 element (15L & 25L).
Neutral
Earth
Live Phase 1
Live Phase 2
Electrical connection for units
with 2 elements (40L models).
Installation Procedures
Fig.1
Fig.2