Warning: this appliance must be earthed.
Following remedial service the earthing continuity of the heater must
be checked by a qualified technician using an appliance tester, or
continuity tester of accuracy Class 5 or better. Class 5 denotes an
accuracy of 5% full scale deflection.
1. Isolate power supply.
2. Set meter to 0 ohm with leads connected together.
3. Connect one test lead to the earth pin on the three pin plug.
4. Connect the other test lead to a bare patch of metal (preferably on
the edge) of the top of the cover, then to the front cover of the unit,
and then to the tap.
Warning- the water may be boiling - show extra care.
5. Test that in every instance the electrical resistance does not exceed
1 ohm.
Earthing Continuity Verification
If required, an earth continuity
test can be performed by testing
between the earth pin on the
products lead and a exposed
piece of metal on the case and
the tap body.
Error Code
Error meaning
Solutions
0
Boiling sensor is open circuit
Call Zip Service
1
Boiling sensor has a short circuit
Call Zip Service
2
Steam Sensor is open circuit
Call Zip Service
3
Steam sensor has a short circuit
Call Zip Service
4
Calibration error !!
Call Zip Service
5
Boiling calibration error, insuffi
cient steam
temperature when boiling sensor registered over
90°c
Call Zip Service
6
Max temp error. The maximum temperature
reached is lower than 92°c during the calibration
process.
Check your height above sea level.
Call Zip Service.
7
Over temp error. A constant temperature over
103°C has been reached during the calibration
process.
Make sure there is an airgap in the vent
line.
Call Zip service.
8
Calibration error, water temperature is falling
or constant when maximum element power is
applied.
When water runs from the outlet tap turn
water supply off to unit. Restart calibration.
Fault Codes Table