Warning: this appliance must be earthed. 

Following remedial service the earthing continuity of the heater must 
be checked by a qualified technician using an appliance tester, or 
continuity tester of accuracy Class 5 or better. Class 5 denotes an 
accuracy of 5% full scale deflection.

1. Isolate power supply.

2. Set meter to 0 ohm with leads connected together.

3. Connect one test lead to the earth pin on the three pin plug.

4. Connect the other test lead to a bare patch of metal (preferably on 
the edge) of the top of the cover, then to the front cover of the unit, 
and then to the tap.

Warning- the water may be boiling - show extra care.

5. Test that in every instance the electrical resistance does not exceed 
1 ohm.

Earthing Continuity Verification

If required, an earth continuity 
test can be performed by testing 
between the earth pin on the 
products lead and a exposed 
piece of metal on the case and 
the tap body.

Error Code

Error meaning

Solutions

0

Boiling sensor is open circuit

Call Zip Service

1

Boiling sensor has a short circuit

Call Zip Service

2

Steam Sensor is open circuit

Call Zip Service

3

Steam sensor has a short circuit

Call Zip Service

4

Calibration error !!

Call Zip Service

5

Boiling calibration error, insuffi

  cient steam 

temperature when boiling sensor registered over 
90°c

Call Zip Service

6

Max temp error. The maximum temperature 
reached is lower than 92°c during the calibration 
process.

Check your height above sea level.
Call Zip Service.

7

Over temp error. A constant temperature over 
103°C has been reached during the calibration 
process.

Make sure there is an airgap in the vent 
line. 
Call Zip service.

8

Calibration error, water temperature is falling 
or constant when maximum element power is 
applied.

When water runs from the outlet tap turn 
water supply off  to unit. Restart calibration. 

Fault Codes Table

Summary of Contents for Autoboil 315052

Page 1: ...l 15 Litre White 313051 Zip Autoboil 15 Litre Stainless Steel 325052 Zip Autoboil 25 Litre White 325051 Zip Autoboil 25 Litre Stainless Steel 340052 Zip Autoboil 40 Litre White 340051 Zip Autoboil 40...

Page 2: ...ensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety For p...

Page 3: ...heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguide does not of...

Page 4: ...de whether to install with concealed or exposed plumbing and or electrical connections Concealed connections are preferred for superior appearance Step 1 Positioning Position the heater so the tap wil...

Page 5: ...t the operation of the heater It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 70...

Page 6: ...cable entry gland at the bottom of the unit to the terminal block within the heater Ensure the cable is firmly secured Thread Tape 2 Ensure sufficient thread tape is applied to the thread 1 Fit the co...

Page 7: ...low into the tank 3 Once the filter flush is complete rotate the valve lever 1800 either way to the FILTERED position Fig 4 Filling Tank 1 Depress the lever as shown in Fig 4 2 Open the tap push the l...

Page 8: ...n 40 Litre models 60 min 64 min Calibrating Completed 7 When it completes as prompted turn on the mains water supply 8 Select to Continue 9 The home screen will be shown see section 2 1 10 The tank wi...

Page 9: ...ng Icons and Buttons Move to the next item able to be highlighted Move to the previous item able to be highlighted Confirm menu selection Move to the previous menu Perform one of 3 functions 1 Move to...

Page 10: ...t Sleep Mode Indication Unit will enter sleep mode at the time shown Unit will enter sleep mode when it is dark All sleep saving modes are disabled 2 2 Sleep Mode Trigger Indication Unit will exit sle...

Page 11: ...Select on the home screen to navigate to the main menu Choose Settings and select Choose an option and select 2 3 Sleep Override Mode Awake time remaining Unit will return back to sleep mode after th...

Page 12: ...prevent excessive steam release or high energy usage see section 4 2 3 3 Settings Sleep Modes From the settings menu choose Sleep Modes and select g Choose Sleep Trigger and select and to select the...

Page 13: ...imer settings for the 2 weekend days simultane ously Adjust on off timer settings for the 7 days separately Weekdays Weekends Individual Days 3 3 3 Timer Settings Individual Days Settings Choose item...

Page 14: ...u and on the home screen are based on these 2 parameters This action will reset the filter usage counter A re minder is shown to flush the new filter before doing this see page 21 Filter Replacement S...

Page 15: ...wever the installation environment may have changed requiring recalibration of the boiling point Incorrect boiling calibration points may cause excessive steam vent releases or increased energy usage...

Page 16: ...t 5 2 Info Current Fault From the info menu choose Current Fault 6 Service Menu Note The service menu is used by technicians only for diagnostic purposes Menu Operation 5 Info Menu Select on the home...

Page 17: ...333 00 10lt 15lt 25lt 591 00 10lt 15lt ExternalPlumbing ElectricalWiring InternalPlumbing 499 00 40lt 39 50 10lt 15lt 25lt 40lt 459 50 40lt 145 00 10lt 15lt 25lt 458 00 40lt 10 00 10lt 15lt 25lt 40lt...

Page 18: ...er Head Kit no bracket 17 94612 Mains Inlet Assy 18 93704 0 2 mic Zip Filter Size 2 19 94613 Steam Sensor NTC Item Kit Number Description 20 90501 Tap Top Assy 21 93730 Flow Insert 22 94478 Tap Body 2...

Page 19: ...805194 09 17 1 02 Page 19 of 24 Exploded View Diagram...

Page 20: ...ection 3 3 or reset settings from service menu Check power supply Contact Zip authorised agent Runs out of boiling water and fails to refill Outlet tap drips Overflow from vent Excessive steam from ve...

Page 21: ...y testing between the earth pin on the products lead and a exposed piece of metal on the case and the tap body Error Code Error meaning Solutions 0 Boiling sensor is open circuit Call Zip Service 1 Bo...

Page 22: ...3 Replace Filter section for details of menu operation Warning Not changing filtration cartridges when required may cause the water to become biologically unsafe If the Zip Autoboil is switched off f...

Page 23: ...not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or sponge and mild soapy water Dispose of the filter cartridge responsibly Use only Zip Filter in this product to e...

Page 24: ...one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The...

Reviews: