Zip AquaFlo II Installation, Maintenance And User Instruction Download Page 8

 

 

WARRANTY 
 

The AquaFlo stainless steel vessel carries a transferable 25 year 
warranty against faulty materials or manufacture provided that: 

  It  has  been  correctly  installed  by  a  competent  installer  as  per  this 

document and all the relevant standards, regulations and codes 
of practice in force at the time. 

  It has not been modified in any way, other than by Zip Heaters 

(UK) Ltd. 

  No components supplied with the AquaFlo have been removed 

for unauthorized repair or replacement. 

  It has not been misused, tampered with or subjected to neglect. 

  It has only been used for the storage of potable water. 

  It has not been subjected to frost damage. 

  The unit has been serviced annually. 

  The system is fed from a public water supply. 

  The warranty period commences from the date of purchase 

subject to registration of the product within 60 days of installation. 

Please note that invoices for servicing may be requested to prove 
that the unit has been serviced annually. All the components fitted 
to/or supplied with the AquaFlo carry a 2 year warranty. 

 
.

EXCLUSIONS –THE WARRANTY DOES NOT 
COVER 

The  effects  of  scale  build  up.  Any  labour  charges  associated 
with replacing the  unit  or its  parts.  Any consequential losses 
caused by the failure or malfunction of the unit. 

IN THE EVENT OF A PROBLEM CONTACT ZIP 
HEATERS ON 0845 602 4533 FOR ADVICE 

USER INSTRUCTIONS 

Your stainless system is automatic in normal use and requires 
only  annual  servicing.  You  should  employ  a  competent 
installer to perform the annual servicing.  

Zip Heaters service department can be contacted on 0845 602 
4533 to arrange servicing or repair. 

IF  WATER  IS  FLOWING  FROM  THE  SAFETY 
VALVES 

THROUGH 

THE 

TUNDISH 

THIS 

INDICATES  A  FAULT  CONDITION  AND ACTION IS 
NEEDED. 

If  this  water  is  hot  turn  the  boiler  and/or  the  immersion 
heater  off.  Do  not  turn  off  the  water  until  the  discharge  runs 
cool. The discharge may also stop. 

CONTACT ZIP HEATERS ON 0845 602 4533 OR 
CALL A COMPETENT PLUMBER OUT TO SERVICE 
THE UNIT. 

 

Tell them you have a fault on an unvented cylinder.  
Zip Heaters stock all the spare parts that may be required

 

Summary of Contents for AquaFlo II

Page 1: ...nance and User Instructions AquaFlo II Issue 3 December 2011 Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater Please leave these instruction...

Page 2: ...ler holding their G3 unvented qualification The installation of this product is also notifiable under the national building regulations The electrical installation including earthing and cross bonding...

Page 3: ...ould be remembered that for every 1 meter that an outlet is above the AquaFlo the pressure will be reduced by 0 1 bar If siting outside the heated envelope of the dwelling such as in a garage or outbu...

Page 4: ...e necessary to incorporate an extra expansion vessel into the circuit to accommodate the increased system water volume in larger secondary circulation systems Where off peak electrical tariffs are bei...

Page 5: ...ervices supplying water for domestic use within buildings and their curtilages b Have a vertical section of pipe at least 300mm long below the tundish before any elbows or bends in the pipework c Be i...

Page 6: ...Black O Orange G Y Green Yellow Br Brown L Live N Neutral C Common SL Switched Live E Earth 3 Port mid position Cutout combined duostat 2 Port DHW C E 2 1 Br G Bl O G Y 1 2 3 Br G Bl O GY 1 2 3 C E 2...

Page 7: ...d be fully opened one at a time then both together allowing as much water as possible to flow through the tundish Check that your discharge pipework is free from debris and is carrying the water away...

Page 8: ...serviced annually All the components fitted to or supplied with the AquaFlo carry a 2 year warranty EXCLUSIONS THE WARRANTY DOES NOT COVER The effects of scale build up Any labour charges associated w...

Page 9: ...1 74 16 46 12 0 1 0 1 07 AF4120 118 915 30 148 105 16 46 16 0 1 0 1 23 AF4150 148 1102 38 186 132 18 55 17 2 1 0 1 41 AF4180 178 1290 42 220 160 18 55 20 4 1 0 1 53 AF4210 208 1478 45 253 188 18 55 22...

Page 10: ...t to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use or installation of this product Zip Heaters UK Ltd 14 Bertie Ward Way Dereh...

Reviews: