Zip AquaFlo II Installation, Maintenance And User Instruction Download Page 2

 

  

INTRODUCTION 

The  corrosion  resistant  AquaFlo  Unvented  cylinder  is  made  from 
Duplex  Stainless  Steel.  It  is  highly  insulated  with  environmentally 
friendly foam enclosed in a rust resistant white steel case. 

It  is  available  in  Direct  and  Indirect  versions  in  a  family  of  7  sizes 
from 90 – 300 litres. Twin Coil and Solar Direct units are available in 5 
sizes from 150 - 300 litres. 

To  help  ensure  compliance  with  the  relevant  Water  and  Building 
Regulations  all  AquaFlo  units  are  supplied  complete  with  the 
necessary safety and control devices needed to connect to the cold 
water  mains.  In  order  to  ensure  high  flow-rate  performance  with 
minimum pressure drop even in lower pressure areas, pre-adjusted, 
high quality controls have been selected. 

AquaFlo is approved to demonstrate compliance with Water 
Regulations and Building Regulations G3 & Part L. 

INSTALLATION PREREQUISITES 

This Cylinder should only be installed by a competent installer 

holding their G3 unvented qualification. The installation of this 

product is also notifiable under the national building regulations. 

The electrical installation including earthing and cross bonding 
must comply with the current IEE regulations and any Local 
Authority requirements. 

ONCE COMPLETED THIS INSTRUCTION MANUAL IN ITS 
ENTIRETY SHOULD BE LEFT WITH THE END USER. 

STORAGE PRIOR TO INSTALLATION 

AquaFlo should be stored upright in a dry area and kept in its 
original packaging until immediately prior to installation. 

COLD INLET SET - WHAT ARE THE CONNECTIONS? 
 

EQUIPMENT SUPPLIED WITH CYLINDER 

 

 

Control & High Limit Cutout Thermostat (Indirect Models Only) 

 

Two Port Zone Valve (Indirect Models Only) 

 

Cold Water Inlet Set 

 

15 x 22mm Tundish 

 

Temperature & Pressure Relief Valve 

 

Expansion Vessel 

 

Expansion Vessel Bracket 

 

500mm Expansion Hose 

 

Immersion Heater(s) - Dependant on size and configuration 

 

Instruction Manual 

 

 

Pressure 

Reducing Valve 

(inc Line Strainer) 

Expansion 

Relief Valve 

Cold Mains In 

Internal 

Check Valve 

Remove Nut For 

Expansion Vessel 
Hose Connection 

Balanced 

Cold Take Off 

Discharge 
To Tundish 

Cold Supply 

To Cylinder 

Summary of Contents for AquaFlo II

Page 1: ...nance and User Instructions AquaFlo II Issue 3 December 2011 Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater Please leave these instruction...

Page 2: ...ler holding their G3 unvented qualification The installation of this product is also notifiable under the national building regulations The electrical installation including earthing and cross bonding...

Page 3: ...ould be remembered that for every 1 meter that an outlet is above the AquaFlo the pressure will be reduced by 0 1 bar If siting outside the heated envelope of the dwelling such as in a garage or outbu...

Page 4: ...e necessary to incorporate an extra expansion vessel into the circuit to accommodate the increased system water volume in larger secondary circulation systems Where off peak electrical tariffs are bei...

Page 5: ...ervices supplying water for domestic use within buildings and their curtilages b Have a vertical section of pipe at least 300mm long below the tundish before any elbows or bends in the pipework c Be i...

Page 6: ...Black O Orange G Y Green Yellow Br Brown L Live N Neutral C Common SL Switched Live E Earth 3 Port mid position Cutout combined duostat 2 Port DHW C E 2 1 Br G Bl O G Y 1 2 3 Br G Bl O GY 1 2 3 C E 2...

Page 7: ...d be fully opened one at a time then both together allowing as much water as possible to flow through the tundish Check that your discharge pipework is free from debris and is carrying the water away...

Page 8: ...serviced annually All the components fitted to or supplied with the AquaFlo carry a 2 year warranty EXCLUSIONS THE WARRANTY DOES NOT COVER The effects of scale build up Any labour charges associated w...

Page 9: ...1 74 16 46 12 0 1 0 1 07 AF4120 118 915 30 148 105 16 46 16 0 1 0 1 23 AF4150 148 1102 38 186 132 18 55 17 2 1 0 1 41 AF4180 178 1290 42 220 160 18 55 20 4 1 0 1 53 AF4210 208 1478 45 253 188 18 55 22...

Page 10: ...t to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use or installation of this product Zip Heaters UK Ltd 14 Bertie Ward Way Dereh...

Reviews: