Zip 802261 Installation Instructions Manual Download Page 8

Page 8 of 16 

   802261 - Residential HT- CO Installation Instructions - March 2016 -  V3.00

Before installing ensure that the following have been provided at the installation 
site:

• 

Review all the technical specifications.

• 

Ensure the underbench can support the product weight when full of water,                                   
(allow an extra 3 kg when full. )

• 

Sufficient space in the cupboard to install all of the undersink units in accordance with these Installation 
Instructions. Refer to technical specification for dimensions. Refer to section 3 & 4, for Installation 
instructions. 

• 

The chilled HydroTap model requires a 220-240 Vac, 10A GPO 

NOTE: Check all cable and hose lengths against inlet /outlet  positions before 
proceeding

  (See section 3 for general layout).   

• 

A potable water supply connection with isolating valve inside the cupboard within reach of the braided 
hoses and positioned so that the connection point and the stop cock will not be obstructed when the 
undersink units are installed. 

• 

A cold water supply with a minimum working pressure of 172kPa and a maximum working pressure of 
700kPa connected via an isolation valve. 

• 

A separate Hot water supply for the Celsius mixer 

• 

The appliance must be placed with it’s base in a horizontal position. 

IMPORTANT!

  Do not proceed with the Installation if these requirements are not met.

   Technical Specifications

Residential models:

C  =  Chilled filtered
CHA = Chilled Hot and Ambient 
D  =  Disabled lever controls, (Order as an option for Classic Tap )

Note: 

the standard Glass measurement =200ml 

Product covered by these instruction:

** Add an extra 3 kg when full of water

Boost 

(10A)

GPO's 

Required

Power 
Rating 

(kW)

Unit Dimensions                               

W x D x H (mm)  

**Dry 

Weight 

(Kg)

Chilled Models

C and CHA

no

1x10A

0.125

280 x 476 x 335

20

Section 1 

Tap Installation

Fit the tap to the benchtop or sink before installing the undersink unit.
Refer to the tap installation book 803341

Summary of Contents for 802261

Page 1: ...ial HT CO Installation Instructions March 2016 V3 00 Page 1 of 16 Zip HydroTap G4 Installation Instructions Affix Model Number Label Here 802261 Filtered Chilled drinking water for residential kitchen...

Page 2: ...interchangeable taps to suit the customer s needs See options below For ease of installation it is recommended to fit the tap before installing the undersink unit The installation procedure for each o...

Page 3: ...ion Instructions STEP 1 Measure and cut all the tap holes before fitting the taps Section 1 Tap Installation instructions 1 HydroTap Tap installation 8 STEP 2 Check for adequate ventilation Section 2...

Page 4: ...ard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have...

Page 5: ...a conventional refrigerant compressor to chill the water which is factory set to 6 10 C These units are NOT designed to be used for sanitary fixtures The water filter is a disposable item which will r...

Page 6: ...persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and un...

Page 7: ...tap shown 1 off HydroTap Undersink Unit with water filter 1 off Mains water connection hose 1 x Inlet vent 1 x Outlet vent 9 x Screws 1 x User guide 1 x Installation Instructions 1 x Tee piece for Ce...

Page 8: ...es and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed A cold water supply with a minimum working pressure of 172kPa and a maxim...

Page 9: ...ement is for a 50mm air gap either side and 300mm above of the undersink unit It is important that the 4mm door buffers For all installations are fitted to the inside edge of the cupboard door to allo...

Page 10: ...sary to fit a standard HydroTap vent kit which ensures heat dissipation through natural convection via installed vents For high use applications where the cupboard space temperature is near 35 C or hi...

Page 11: ...ndersink Unit Installation BLUE BRAIDED 3 1 Hose and tube fitting Do not overtighten Remove all caps from the top of the undersink unit Install the mains water braided hoses to the undersink unit befo...

Page 12: ...size They must have a constant fall back to the unit BLUE BRAIDED Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap within reach of th...

Page 13: ...ow at least 10 litres of water to flush through the filter 4 Once the filter flush is finished Turn the stop cock OFF then press Stop to end filter flush mode Have a 10L bucket or similar container no...

Page 14: ...too Hot Check ventilation Water Supply Failure No water Check water supply is turned ON Cold Sensor Open Internal fault Call Zip Service Cold Sensor Closed Internal fault Call Zip Service Flood Senso...

Page 15: ...ation Instructions March 2016 V3 00 Page 15 of 16 In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection cent...

Page 16: ...49 US5103859 US5099825 and SA2006 08043 Other patents are in force and patent applications are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200...

Reviews: