WARNINGS

1. 

The Zip HydroTap unit must be earthed. The resistance of the earth connection from each exposed 
metal part must be less than 1 ohm.

2. 

All Installation and service work must be completed by trained and suitably qualified Tradespeople. 
Faulty operation due to unqualified persons working on this product, or any other Zip product may void 
warranty coverage.

3. 

All Plumbing must comply with AS/NZS3500.

4. 

All Electrical must comply with AS/NZS3000

5. 

All Plumbing and Electrical connections must be made in accordance with local regulations.

6. 

This HydroTap product is rated for 230V 50Hz AC operation.

7. 

Undersink units must never be located near, or cleaned with water jets.

8. 

Zip HydroTaps are not to be exposed to the elements of nature

9. 

Due to the process of continuous improvement, Zip Heaters reserves the right to change details 
mentioned in this manual, without notice.

Important Safety Instructions

This manual contains important safety, installation instructions for the Zip HydroTap G4.
This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge 
if they have been given supervision or instruction concerning use of the appliance in a safe way and 
understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance 
shall not be made by children without supervision.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all 
installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power 
outlet must be in a safe visible position for connection.

Lifting

Take care when lifting the Zip HydroTap unit. Some units may exceed safe lifting limits. If you feel this is 
beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked 
on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to 
page 7 for the weight of your product. 

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. Proper air circulation must be 
provided. The system will operate satisfactorily only if the recommended air gaps are provided. If a vent kit is 
supplied it must be fitted. See technical specifications for correct installation to prevent overheating. 

Positioning

It is important to ensure the undersink unit is positioned in an accessible area close to the floor level. The unit 
must have it’s base mounted in a horizontal position with all inlets and outlets facing up. The Tap must be 
located above the undersink unit. See section 1.

ef nature. This unit must not be positioned in an area 

that may be cleaned by a water jet and must not be cleaned by a water jet.

                                                            

Summary of Contents for 802261

Page 1: ...ial HT CO Installation Instructions March 2016 V3 00 Page 1 of 16 Zip HydroTap G4 Installation Instructions Affix Model Number Label Here 802261 Filtered Chilled drinking water for residential kitchen...

Page 2: ...interchangeable taps to suit the customer s needs See options below For ease of installation it is recommended to fit the tap before installing the undersink unit The installation procedure for each o...

Page 3: ...ion Instructions STEP 1 Measure and cut all the tap holes before fitting the taps Section 1 Tap Installation instructions 1 HydroTap Tap installation 8 STEP 2 Check for adequate ventilation Section 2...

Page 4: ...ard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have...

Page 5: ...a conventional refrigerant compressor to chill the water which is factory set to 6 10 C These units are NOT designed to be used for sanitary fixtures The water filter is a disposable item which will r...

Page 6: ...persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and un...

Page 7: ...tap shown 1 off HydroTap Undersink Unit with water filter 1 off Mains water connection hose 1 x Inlet vent 1 x Outlet vent 9 x Screws 1 x User guide 1 x Installation Instructions 1 x Tee piece for Ce...

Page 8: ...es and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed A cold water supply with a minimum working pressure of 172kPa and a maxim...

Page 9: ...ement is for a 50mm air gap either side and 300mm above of the undersink unit It is important that the 4mm door buffers For all installations are fitted to the inside edge of the cupboard door to allo...

Page 10: ...sary to fit a standard HydroTap vent kit which ensures heat dissipation through natural convection via installed vents For high use applications where the cupboard space temperature is near 35 C or hi...

Page 11: ...ndersink Unit Installation BLUE BRAIDED 3 1 Hose and tube fitting Do not overtighten Remove all caps from the top of the undersink unit Install the mains water braided hoses to the undersink unit befo...

Page 12: ...size They must have a constant fall back to the unit BLUE BRAIDED Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap within reach of th...

Page 13: ...ow at least 10 litres of water to flush through the filter 4 Once the filter flush is finished Turn the stop cock OFF then press Stop to end filter flush mode Have a 10L bucket or similar container no...

Page 14: ...too Hot Check ventilation Water Supply Failure No water Check water supply is turned ON Cold Sensor Open Internal fault Call Zip Service Cold Sensor Closed Internal fault Call Zip Service Flood Senso...

Page 15: ...ation Instructions March 2016 V3 00 Page 15 of 16 In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection cent...

Page 16: ...49 US5103859 US5099825 and SA2006 08043 Other patents are in force and patent applications are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200...

Reviews: