Page 6 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
3.
Classic HydroTap
®
G4
(inc. All -in One)
To dispense sparkling water
Press both blue CHILLED and red BOILING levers together, simultaneously to
dispense sparkling water.
Pulling forward the blue CHILLED and red BOILING levers together allows the
tap to operate in a “no-touch” mode. Water will flow from between 5 and 15
seconds (this is user adjustable, see page 23).
To reset, return the lever to the OFF position and repeat the step. The lever
has to be manually returned to the OFF position.
Pull both levers forward
Safety
sensor
•
Shield the HydroTap
®
G4 from any
direct sunlight.
•
With the Command-Centre
TM
in
normal operating mode and safety
lock enabled, turn the power off.
•
Pull both tap levers to the forward
position.
•
Turn the power on.
•
The Command-Centre
TM
will calibrate
the safety switch.
•
Return the levers to the neutral
position.
Safety sensor calibration
Light intensity varies from site to site, therefore it is recommended that a
recalibration be performed at the time of the installation.
All direct sunlight must be shaded from the HydroTap
®
G4, during the
calibration. This can be achieved by closing any nearby curtains, blinds, etc.
Arc and Cube HydroTap
®
G4
Indicator light
Select button
Safety button
Rotary
control
Arc / Cube functionality
On power up, wait 30secs. for the unit to
calibrate before selecting either the BOILING
red illuminated with safety, CHILLED
blue or SPARKLING white illuminated
water mode, by touching the select
button.
The Arc / Cube control may be rotated in a forward
or reverse direction to
dispense water.
The rotary control is spring loaded in the forward
direction and when released, will return to the OFF
position.
When rotated in the reverse direction the tap
operates in a POT FILL mode. Water will flow from
between 5 and 15 seconds (This is user adjustable,
see page 23). To reset, return the control to the
OFF position and repeat the step. The control has to be manually returned to