807062 v1.00 03.21 EB HB Install Instructions

TECHNICAL SPECIFICATION

Before installation, ensure that:

•  All technical specifications and instructions have been reviewed and understood.
•  The mounting wall can support the product weight when full of water. See Technical 

specifications.

•  Sufficient space is provided to install the appliance and other components in accordance 

with these installation instructions. Check cable and plumbing against inlet /outlet  
positions before proceeding.

•  An easily accessible socket and double pole isolation switch (correctly rated for the 

appliance) is required. For models rated below 3kW: 220-240V AC 50-60Hz; for models 
rated above 3kW: 380-415V AC mains power.

•  The appliance must be connected to a potable water supply with working pressure of: AU/

NZ 150 - 700 kPa (1.5 - 7.0 bar); UK 70 - 500 kPa (0.7 - 5.0 bar).

•  The appliance must be connected with an isolating valve within reach of the hose and 

positioned so that the valve will not be obstructed.

•  A 350 kPa (3.5 bar) pressure limiting valve (not supplied) must be fitted if the incoming 

mains water pressure is likely to exceed 500 kPa (5.0 bar)

•  The appliance must be placed upright with its base in a horizontal position.

IMPORTANT! Do not proceed with the installation if these 
requirements are not met.

Tank 

size

(litres)

Heat up 

time 

(Inlet 

15°C) 

Heat up 

time 

 (Inlet 

10°C)

Rated voltage and power

Dimensions 

W x D x H

(mm)*

Filled 

weight

(kg)

3.0

16mins

17mins

220-240V, 50Hz, 1400W

220V, 60Hz, 1250W

300 x 183 x 439

12

5.0

16mins

17mins

220-240V, 50Hz, 2200W 

220V, 60Hz, 2000W

329 x 201 x 473

15

7.5

23mins

23mins

329 x 201 x 586

20

10.0

40mins

43mins

220-240V, 50Hz, 2800W 

220V, 60Hz, 2500W

401 x 249 x 606

27

15.0

40mins

43mins

401 x 301 x 606

33

25.0

47mins

50mins

401 x 301 x 786

47

40.0

60mins

64mins

220-240V, 50Hz, 5400W

220V, 60Hz, 4800W

380-415V, 2N, 50Hz, 5600W 

380V, 2N, 60Hz, 5000W

526 x 286 x 847

70

!

* add 98mm to Depth for Tap and Fascia (Econoboil AU, Hydroboil)
   add 96mm to Depth for Tap (no Fascia) (All other Econoboil)

Summary of Contents for 403042

Page 1: ...1 807062v1 0003 21EBHBInstallInstructions Installation instructions Zip Econoboil Hydroboil Onwallboilingwater Models Econoboil 3L 5L 7 5L Hydroboil 3L 5L 7 5L 10L 15L 25L 40L...

Page 2: ...NSTRUCTIONS 3 WARNINGS PRECAUTIONS 4 TECHNICAL SPECIFICATION 5 Step 1 Positioning 6 Step 2 Fastening 7 Step 3 Plumbing connection 9 Step 4 Electrical connection 10 Step 5 Assembly 12 Step 6 Commission...

Page 3: ...enting Occasionally steam and or boiling water may discharge through a vent outlet or the tap Ensure the tap body is located so the tap outlet safely dispenses into the drip tray or sink bowl area and...

Page 4: ...pliance under any circumstances without first isolating the appliance from the power supply 9 The cold water supply to this appliance must be potable and fall within your local authority guidelines 10...

Page 5: ...within reach of the hose and positioned so that the valve will not be obstructed A 350 kPa 3 5 bar pressure limiting valve not supplied must be fitted if the incoming mains water pressure is likely to...

Page 6: ...oles for concealed plumbing water inlet vent outlet and electrical 1 2 1 3 Observe clearance around the appliance for service access Mark corners of the appliance on the wall x x x x 1 1 100mm 3L 5L 7...

Page 7: ...7 807062v1 0003 21EBHBInstallInstructions Step 2 Fastening 3 7 5 litre models 10 40 litre models Remove cover screws Remove the cover Use supplied screws to mount the appliance to the wall 2 1...

Page 8: ...stallInstructions 3 7 5 litre models Strain relief bush cable gland Terminal block Escutcheon Tap nut Tap Concealed access 10 40 litre models Strain relief bush cable gland Concealed access Filter AU...

Page 9: ...vent outlet IMPORTANT Coldwaterpipesmustbeflushedbeforeconnectiontotheinlettopreventblockagesfrom affectingoperationoftheappliance Anisolationvalve notsupplied mustbefittedtothewatersupply AllVentpipe...

Page 10: ...and attach to the chassis earth male terminal An isolation switch should be installed according to AS3000 Do not turn power ON until the appliance can dispense water from the tap outlet Verify the ear...

Page 11: ...and L2 is required Heating Element Key x x number of wires Red Red wire Blu Blue wire Blk Black wire Grn Green wire Yel Yellow wire Brn Brown wire Mains input 806010 v3 Electrical Wiring Diagram Hydro...

Page 12: ...BInstallInstructions Step 5 Assembly Refit cover Fix with screws top and bottom Apply thread tape to thread Turn tap until it touches the lock nut and is upright Use spanner supplied to tighten the lo...

Page 13: ...er to reach boiling set temperature 6 2 6 3 Check earthing Earthing continuity must be tested by a qualified technician using a resistance meter of minimum accuracy of 5 full scale deflection Ensure e...

Page 14: ...ns Tap operation Hydroboil and Econoboil are fitted with a two way cool touch tap Boiling water will be dispensed Press lever to dispense boiling water Push to lock for continuous flow If lever does n...

Page 15: ...Overload repeatedly tripping with excessive steam Overload repeatedly tripping without excessive steam Internal adjustment Contact Zip authorised agent In the event of a fault or failure isolate power...

Page 16: ...prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2021 Zip Water Aust Pty Ltd Zip Water Aust Pty Ltd ABN 46 000 578 727 67 77 Allingham...

Reviews: