807062 v1.00 03.21 EB HB Install Instructions

WARNINGS & PRECAUTIONS

1.  For continued safety of this appliance it must be installed, operated and 

maintained in accordance with the manufacturer’s instructions.

2.  This appliance may deliver water at high temperature. Refer to the Plumbing 

Code of Australia (PCA), local requirements and installation instructions to 

determine if additional delivery temperature control is required.

3.  All plumbing and electrical connections must be made in accordance with local 

regulations and relevant standards. For Australia/NZ: electrical installation must 

comply with AS/NZS 3000. For Australia/NZ:, plumbing installation must comply with 

Plumbing standard AS/NZS 3500. UK: the system must be installed in accordance with 

water supply byelaws, current IEEE regulations and local authority byelaws.

4.  All installation and service work must be completed by trained and suitably 

qualified tradespeople. Faulty operation due to unqualified persons working on 

the product may void warranty coverage. 

5.     This appliance must be earthed. The resistance of the earth connection 

from each exposed metal part must be less than 1 ohm.

6.  The power cord and general power outlet must be in a safe and accessible 

position after installation. 

7.  Any disconnection to the fixed wiring must be in accordance with local 

regulations and relevant standards including AS/NZS 3000.

8.  Do not remove the cover of the appliance under any circumstances without 

first isolating the appliance from the power supply.

9.  The cold water supply to this appliance must be potable and fall within your 

local authority guidelines.

10.  The installer is responsible to supply and install all valves as required by local 

regulations and relevant standards. 

11.  In hard water areas where mineral scale accumulation may become a problem, 

consideration should be given to the maintenance required. A suitable form of 

water treatment may be necessary.

12.  This appliance is designed for indoor use and must not be installed outdoors or 

exposed to the elements of nature. 

13.  This appliance must operate within ambient temperatures of 5ºC - 50ºC. 
14.  Do not clean this appliance with a water jet.  Do not position this appliance in 

an area that may be cleaned by a water jet.

15.  This appliance is not intended for use by young children or infirm people 

without supervision. Young children should be prevented from having access 

to ensure that they are not able to use or play with the appliance. 

16.  This appliance is intended to be used in: staff kitchen areas in shops, offices and 

other working environments; farm houses and by clients in hotels, motels and 

other residential type environments; bed and breakfast type environments; 

catering and similar non-retail applications.

17.  Due to the process of continuous improvement, the manufacturer reserves 

the right to change details mentioned in this manual, without notice. Visit the 

website of the manufacturer/distributor to ensure you have the latest copy of this 

document.

Summary of Contents for 403042

Page 1: ...1 807062v1 0003 21EBHBInstallInstructions Installation instructions Zip Econoboil Hydroboil Onwallboilingwater Models Econoboil 3L 5L 7 5L Hydroboil 3L 5L 7 5L 10L 15L 25L 40L...

Page 2: ...NSTRUCTIONS 3 WARNINGS PRECAUTIONS 4 TECHNICAL SPECIFICATION 5 Step 1 Positioning 6 Step 2 Fastening 7 Step 3 Plumbing connection 9 Step 4 Electrical connection 10 Step 5 Assembly 12 Step 6 Commission...

Page 3: ...enting Occasionally steam and or boiling water may discharge through a vent outlet or the tap Ensure the tap body is located so the tap outlet safely dispenses into the drip tray or sink bowl area and...

Page 4: ...pliance under any circumstances without first isolating the appliance from the power supply 9 The cold water supply to this appliance must be potable and fall within your local authority guidelines 10...

Page 5: ...within reach of the hose and positioned so that the valve will not be obstructed A 350 kPa 3 5 bar pressure limiting valve not supplied must be fitted if the incoming mains water pressure is likely to...

Page 6: ...oles for concealed plumbing water inlet vent outlet and electrical 1 2 1 3 Observe clearance around the appliance for service access Mark corners of the appliance on the wall x x x x 1 1 100mm 3L 5L 7...

Page 7: ...7 807062v1 0003 21EBHBInstallInstructions Step 2 Fastening 3 7 5 litre models 10 40 litre models Remove cover screws Remove the cover Use supplied screws to mount the appliance to the wall 2 1...

Page 8: ...stallInstructions 3 7 5 litre models Strain relief bush cable gland Terminal block Escutcheon Tap nut Tap Concealed access 10 40 litre models Strain relief bush cable gland Concealed access Filter AU...

Page 9: ...vent outlet IMPORTANT Coldwaterpipesmustbeflushedbeforeconnectiontotheinlettopreventblockagesfrom affectingoperationoftheappliance Anisolationvalve notsupplied mustbefittedtothewatersupply AllVentpipe...

Page 10: ...and attach to the chassis earth male terminal An isolation switch should be installed according to AS3000 Do not turn power ON until the appliance can dispense water from the tap outlet Verify the ear...

Page 11: ...and L2 is required Heating Element Key x x number of wires Red Red wire Blu Blue wire Blk Black wire Grn Green wire Yel Yellow wire Brn Brown wire Mains input 806010 v3 Electrical Wiring Diagram Hydro...

Page 12: ...BInstallInstructions Step 5 Assembly Refit cover Fix with screws top and bottom Apply thread tape to thread Turn tap until it touches the lock nut and is upright Use spanner supplied to tighten the lo...

Page 13: ...er to reach boiling set temperature 6 2 6 3 Check earthing Earthing continuity must be tested by a qualified technician using a resistance meter of minimum accuracy of 5 full scale deflection Ensure e...

Page 14: ...ns Tap operation Hydroboil and Econoboil are fitted with a two way cool touch tap Boiling water will be dispensed Press lever to dispense boiling water Push to lock for continuous flow If lever does n...

Page 15: ...Overload repeatedly tripping with excessive steam Overload repeatedly tripping without excessive steam Internal adjustment Contact Zip authorised agent In the event of a fault or failure isolate power...

Page 16: ...prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2021 Zip Water Aust Pty Ltd Zip Water Aust Pty Ltd ABN 46 000 578 727 67 77 Allingham...

Reviews: