10.5 Installing the inductive sensor
INFORMATION
The inductive sensor is used for product safety and can be used to detect the "loose part present" signal.
WWR40 installation size
cp
cm
co
cn
►
Position the mounting piece in the
corresponding fit on the stationary part.
►
Install the mounting piece on the stationary
part with the mounting screw.
►
Install the sensor on the mounting piece
with the mounting screw.
cm
Mounting piece
cn
Mounting piece mounting screw
co
Sensor
cp
Sensor mounting screw
Other installation sizes
cp
co
►
Position the sensor in the corresponding fit
on the stationary part.
►
Install the sensor on the fit with the
mounting screw.
co
Sensor
cp
Mounting screw