10 Installation
WARNING
Risk of injury due to uncontrolled movements
Risk of injury in case of unexpected movement of the machine or system into which the product is to be installed.
►
Switch off the energy supply of the machine before any work.
►
Secure the power supply against being switched on unintentionally.
►
Check the machine for any residual energy that may be present.
CAUTION
Risk of injury due to uncontrolled movements
Risk of injury in the event of uncontrolled movement of the product when the power supply is connected.
►
Switch off the power supply to the machine before carrying out any work.
►
Secure the power supply against being switched on unintentionally.
►
Check the machine for any residual energy that may be present.
NOTICE
►
Please note that when using hose-free connections, the O-rings must be inserted into the customer-made
pockets of the holes on the mounting surface.
►
Note the specified screw lengths.
INFORMATION
Further installation information:
• Mounting screws are included in the scope of delivery.
Assembly requirements
Permissible unevenness [mm]
Mounting surface length [mm] < 100
< 0.02
Mounting surface length [mm] > 100
< 0.05
Strength class of the mounting screws (EN ISO 4762)
8.8
►
You can find the exact installation positions in the technical data sheet on our website.
►
Install the product on an appropriate mounting surface in accordance with the flatness specifications.
►
Make sure that the mounting surface of the product and connection structure are clean.
►
Observe the tightening torque of the mounting screws.
►
Verify the permitted load capacity of the required screw connections in accordance with VDI 2230.
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com