19
10.4.2 WWR80F installation size
Design size
1-point magnetic field sensor
WWR80F
ZUB0018
Design size
2-point magnetic field sensor
WWR80F
ZUB088925
As an example, the figures show the installation
of a 1-point and 2-point magnetic field sensor.
ZUB0018
bq
bo
bp
bs
bt
br
ZUB088925
bq
bt
bp
bo
br
bu
bs
►
Remove the seal.
►
Slide the sensors into the sensor bracket.
►
Securely clamp the sensors with the grub
screw.
►
Position the spacer on the sensor bracket
with the grub screw and the straight pin.
►
Install the components with the mounting
screw.
►
Insert the sensor bracket into the opening
on the stationary part up to the end stop.
►
Secure the sensor bracket into position from
above with the grub screws.
bo
Sensor
bp
Sensor bracket
bq
Grub screw
br
Spacer
bs
Straight pins
bt
Mounting screw
bu
Grub screw
INSTALLATION AND OPERATING INSTRUCTIONS:
WWR
DDOC00227 / p
EN / 2023-05-15
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
Summary of Contents for WWR Series