30
12 Service life
INFORMATION
►
Please note that depending on the application case and environmental conditions, the achievable number of
cycles can be over or under the tested number of cycles.
The service life depends on the following factors:
• Application
• Load case and/or installation situation
• Energy load
• Stroke application
• Ambient conditions
The products are continually tested in an internal endurance test, where the energy load per hour and the installation
situation correspond to the worst-case conditions.
The test takes place in a clean environment and at a room temperature of 20–25 °C.
The following values were determined under laboratory conditions:
Product series
Operating cycles
Mini Energy
5 million
Standard Energy
10 million
High Energy
15 million
Adjustable Energy
15 million
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
INSTALLATION AND OPERATING INSTRUCTIONS:
PowerStop
DDOC00335 / b
EN / 2023-08-07
Summary of Contents for PowerStop PHE16X10LSAK-A
Page 2: ......