12. Maintenance
Maintenance-free operation of the gripper is guaranteed for up to
10 million cycles
.
The maintenance interval may shorten under the following circumstances:
• Dirty environment
•
Improper use and use that does not comply with the power specifications.
•
Observe ambient temperature; lubricants harden faster!
Even though the gripper is, as mentioned, maintenance-free, perform a regular visual inspection to check for any
corrosion, damage or contamination.
We recommend using the Zimmer Customer Service for maintenance and the replacement of seals.
Dismantling and reassembling the gripper without authorization may result in complications, as special installation
equipment is required in some cases.
Zimmer GmbH shall not be liable in the event of unauthorized dismantling and reassembling of the gripper or in the
event of any malfunction or damage resulting from this.
13. Accessories/scope of delivery
INFORMATION:
If any accessories not marketed or authorized by Zimmer GmbH are used, the function of the gripper
cannot be guaranteed.
The accessories from Zimmer GmbH are specifically fitted for the individual grippers.
For information on corresponding accessories, please visit our website.
14. Transportation/storage/preservation
►
The transport and storage of the gripper must take place exclusively in the original packaging.
►
If the gripper has already been installed on the higher-level machine unit, it must be ensured during transport that no
unintentional movements may take place. Before commissioning the machine after transport, check all power and
communication connections as well as all mechanical connections.
►
If the product is stored for an extended period, the following points are to be observed:
Ö
Keep the storage location as dust-free and dry as possible.
Ö
Avoid temperature fluctuations/observe and adhere to the temperature range.
Ö
Avoid wind/drafts/water condensation formation.
Ö
Package the product.
Ö
During storage, it must be kept from direct sunlight.
►
Clean all components. There must be no impurities left on the components.
►
Visually inspect all of the components.
►
Remove all foreign objects.
►
Properly remove potential corrosion spots.
►
Close electrical connections using suitable covers.
15. Decommissioning and disposal
INFORMATION:
If the gripper reaches the end of its operational phase, the gripper can be completely disassembled
and disposed of. Disconnect the gripper from the power supply completely. The gripper can be
disassembled and properly disposed of according to material groups. When disposing of it, observe
the locally applicable environmental regulations and codes and regulations for disposal.