background image

6

Personnel qualification

Installation, commissioning and maintenance may only be performed by trained specialists. These persons must have read 

and understood the installation and operating instructions in full.

5  Product description

5.1  Type plate

A type plate is attached to the housing of the product.

XXX

XX-XXXXXX

am
an

The article number and the confirmation number are shown on the type 

plate.

am

Article number

an

Confirmation number

6  Functional description

The product has a double-acting pneumatic rotor cylinder.
Alternating ventilation sets the gripper jaws in motion.
The movement generated in this process is transferred to the gripper jaws by kinematics, producing the gripper jaw 

movement.

7  Technical data

INFORMATION

 

You can find the information in the technical data sheet on our website.

This data varies within the series, depending on the specific design.

 

Please contact Zimmer Customer Service if you have any questions.

8  Accessories/scope of delivery

INFORMATION

If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be 

guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products.

 

For optional accessories and those included in the scope of delivery, refer to our website.

9  Transportation/storage/preservation

 

Transport and storage of the product must be done only with the original packaging.

 

If the product has already been installed on the superordinate machine unit, care must be taken during transport to 

ensure that no unexpected movements can occur. 

 

Before commissioning the product and after transport, check all power and communication connections as well as 

all mechanical connections.

 

If the product is stored for an extended period, the following points are to be observed:

 

Keep the storage location as dust-free and dry as possible.

 

Avoid temperature fluctuations.

 

Avoid wind/drafts/water condensation formation.

 

Pack the product and do not expose it to direct sunlight during storage.

 

Clean all components. There must be no soiling left on the components.

 

Visually inspect all components.

 

Remove all foreign substances.

 

Properly remove potential corrosion spots.

 

Close off unused connections using pressure-resistant closures.

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

INSTALLATION AND OPERATION INSTRUCTIONS: 

GH6000

DDOC00274 / e

EN / 2023-02-13

Summary of Contents for GH6000

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS 2 jaw parallel gripper with long stroke pneumatic GH6000 DDOC00274 THE KNOW HOW FACTORY www zimmer group com...

Page 2: ......

Page 3: ...torage preservation 6 10 Installation 7 10 1 Installing the product 8 10 2 Installing the energy supply 8 10 3 Installing the sensors 9 10 3 1 Adjusting the magnetic field sensors 9 10 3 2 Setting the...

Page 4: ...ding these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Page 5: ...ried out on the product make sure that the product cannot be actuated by mistake Perform maintenance tasks renovation work or attachment work outside of the machine s danger zone when possible Do not...

Page 6: ...ranteed Zimmer GmbH accessories are specifically tailored to the individual products For optional accessories and those included in the scope of delivery refer to our website 9 Transportation storage...

Page 7: ...present NOTICE Installation may only be carried out by qualified personnel in accordance with these installation and operating instructions Switch off the power supply before any assembly installatio...

Page 8: ...of delivery refer to our website 10 2 Installing the energy supply NOTICE You can find the information in the technical data sheet on our website Close off unused connections using pressure resistant...

Page 9: ...essories and those included in the scope of delivery refer to our website Switch off the power supply 1 2 3 Slide the sensor into the terminal block Position the sensor at an appropriate switching dis...

Page 10: ...free operation of the product can be reduced under the following circumstances Operation with impermissible compressed air Dirty environment Improper use and use that does not comply with the power s...

Page 11: ...e specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents f...

Reviews: