2  Safety notices

CAUTION

Risk of injury and material damage in case of non-compliance

Installation, commissioning, maintenance and repairs may only be performed by qualified specialists in 

accordance with these installation and operating instructions.
The product is state-of-the-art.

It is fitted to industrial machines and is used to hold, transport and store workpieces.

The following are examples of situations in which the product may cause a hazard:
•  The product is not properly installed, used or maintained.
•  The product is not used for its designated purpose.
•  The locally applicable regulations, laws, directives or guidelines are not observed.

 

The product may only be used in accordance with these installation and operating instructions and the 

product's technical data. Any changes or additions to the intended use of the product, as well as modifications 

to the product, such as those in the following examples, require the written permission of the manufacturer:
• 

Use of the product under extreme conditions, such as aggressive fluids or abrasive dusts

•  Additional drilled holes or threads

 

Ö

Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole 

responsibility.

 

Make sure that the power supply is disconnected before you mount, adjust, modify, maintain or repair the 

product.

 

Whenever work is carried out on the product, make sure that the product cannot be actuated by mistake.

 

Perform maintenance tasks, renovation work or attachment work outside of the machine's danger zone when 

possible.

 

Do not reach into the operational range of the product.

 

Observe the specified maintenance intervals and specifications regarding the quality of the operating material.

 

When using the product under extreme conditions, adjust the maintenance interval according to the degree of 

contamination.

3  Proper use

NOTICE

The product is only to be used in its original state with its original accessories, with no unauthorized changes and 

within the stipulated parameter limits and operating conditions.
Any other or secondary use is deemed improper.

 

Operate the product only in compliance with the associated installation and operating instructions.

 

Operate the product only when it is in a technical condition that corresponds to the guaranteed parameters 

and operating conditions.

 

Ö

Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole 

responsibility.

The product is designed exclusively for pneumatic operation.
The product is to be used as intended in enclosed rooms for temporary gripping, handling and holding.
The product is not suitable for clamping workpieces during a machining process.
Direct contact with perishable goods/food is not permitted.

INSTALLATION AND OPERATION INSTRUCTIONS: 

GH6000

DDOC00274 / e

EN / 2023-02-13

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Summary of Contents for GH6000

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS 2 jaw parallel gripper with long stroke pneumatic GH6000 DDOC00274 THE KNOW HOW FACTORY www zimmer group com...

Page 2: ......

Page 3: ...torage preservation 6 10 Installation 7 10 1 Installing the product 8 10 2 Installing the energy supply 8 10 3 Installing the sensors 9 10 3 1 Adjusting the magnetic field sensors 9 10 3 2 Setting the...

Page 4: ...ding these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Page 5: ...ried out on the product make sure that the product cannot be actuated by mistake Perform maintenance tasks renovation work or attachment work outside of the machine s danger zone when possible Do not...

Page 6: ...ranteed Zimmer GmbH accessories are specifically tailored to the individual products For optional accessories and those included in the scope of delivery refer to our website 9 Transportation storage...

Page 7: ...present NOTICE Installation may only be carried out by qualified personnel in accordance with these installation and operating instructions Switch off the power supply before any assembly installatio...

Page 8: ...of delivery refer to our website 10 2 Installing the energy supply NOTICE You can find the information in the technical data sheet on our website Close off unused connections using pressure resistant...

Page 9: ...essories and those included in the scope of delivery refer to our website Switch off the power supply 1 2 3 Slide the sensor into the terminal block Position the sensor at an appropriate switching dis...

Page 10: ...free operation of the product can be reduced under the following circumstances Operation with impermissible compressed air Dirty environment Improper use and use that does not comply with the power s...

Page 11: ...e specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents f...

Reviews: