7 Operation and maintenance
33
Version 0.6
2023
NOTE
Simple greasing during operation.
Instead of a grease gun, use an automatically controlled lubricator
(e.g. PLC capable)
ZIMM will be pleased to give advice.
There are different greases for different applications.
• High temperature
• Low temperature
• Food processing industry
• Heavy-duty applications
• etc.
ZIMM will be pleased to give advice.
7.2.5
Automatic lubrication
Ventilate the SML2 lubrication point in a vertical position.
When hanging vertically, ventilate at lubrication point SML1.
When installed horizontally, ventilate as desired (SML1 or SML2).
Sintered metal silencers from pneumatics can be used for ventilation. In this
case, the ZIMM Aktuator loses its IP64 protection rating. For a higher degree of
protection, a different form of ventilation must be used.
NOTE
Controlled lubricator (e.g. PLC capable).
Flow rate of the controlled lubricator from 0.2 ml to 0.5 ml per
lubricant stroke.
Approach lubrication position SP1 or SP2 to ±2 mm.
The opposite side of the lubrication position must be ventilated.
The lubrication point to be ventilated is always at the top.
ZIMM will be happy to advise you.