6 Installation
ZIMM Screw Jack
20
Version 1.2
2015-01
5. Connect the cable ends (5) in accordance with diagram (see
Fig. 13:
Connection diagram for the limit switch
BN Brown
BK Black
BU Blue
BK-WH Black-White
GN-YE Green-Yellow
If necessary the cable outlet can be turned through 180°.
Fig. 14:
Turning the cable outlet of the limit switch
1. Loosen the screws (1) and unscrew them.
2. Pull the limit switch (3) out of its bracket (2) and turn it through 180°.
3. Insert the limit switch into the bracket (2) again.
4. Refit the screws (1) and tighten them.
Fig. 15:
Adjustment of the limit switch
1. Move the screw jack away from the limit switch trigger point.
2. Loosen the screws (1).
3. Adjust the limit switch by sliding it in the direction shown.
4. Tighten the screws (1).
Turning the cable outlet
Adjusting the position of
the limit switch
±5mm