eZ80F92 Development Kit
User Manual
Operational Description
PRELIMINARY
UM013904-0203
34
PB1
The PB1 push button switch, SW2, is connected to bit 1 of GPIO Port B.
This switch can be used as the port input if required by the user.
PB2
The PB2 push button switch, SW3, is connected to bit 2 of GPIO Port B.
This switch can be used as the port input if required by the user.
RESET
The Reset push button switch, SW4, resets the eZ80
®
CPU and the eZ80
®
Development Platform.
Jumpers
The eZ80
®
Development Platform provides a number of jumpers that are
used to enable or disable functionality on the platform, enable or disable
optional features, or to provide protection from inadvertent use.
Jumper J2
The J2 jumper connection enables/disables IrDA transceiver functional-
ity. When the shunt is placed, IrDA communication is disabled. See
Table 13.
Table 13. J2—DIS_IrDA
Shunt
Status
Function
Affected Device
In
IrDA interface disabled UART0 is configured to work with the RS232 or the
RS485 interfaces.
Out
IrDA interface enabled The IrDA and UART0 interfaces on the eZ80F92 Flash
Module perform their functions.