d.
Instructions regarding the Settingss of the Relay for the worm Conveyor Motor
K1 and E1:
Protector with relay for pump
Setting Range: 1,6-2,4 A
(already set)
K2 and E2:
Protector with relay for worm conveyor
Setting Range:
4 - 6 A
depending on motor performance
6 - 10 A
depending on motor performance
10 – 16 A
depending on motor performance
Attention!
The relay E2 must be set to the respective current consumption (Ampere)
of the worm conveyor motor.
In the event of an overload of one of the motors, the relay E1 (pump) or E2 (worm conveyor) will shut
down (the yellow pin will protrude 2mm).
Restart: Actuate the blue round button.
Red Square Button:
Manual triggering by retracting
Blue Round Button, Position: Manual activation via actuation
Position A:
Automatic activation after cooling process of thermal contact is
completed.
Changeover from H to A:
At position H of the blue button, the same must be turned towards A in actuated condition.