background image

18

17.Specications

Reso-
lution

Input impedance

RISH 

Multi

12

13

14

15 16

S

S

S

S

S

 V

V ~

A ~

3.000

V

30.00

V

300.0

V

1000

V

300.0 mA

3.000 mA
30.00 mA

300.0 mA

3.000 A

10.00 A

3.000 mA

30.00 mA

300.0 mA

10.00 A

30.00 A

2)

300.0 A

2)

3.000 mA

300.0 mA

10.00 A

30.00 W

300.0 W

3.000 kW
30.00 kW

300.0 kW

3.000 MW
30.00 MW

2.000 V

1)

1)

1)

1)

16A

16A

1)

1)

1)

1 mV

10 mV

100 mV

1  V

100 nA

1  mA

10 mA

100 mA

1 mA

10 mA

1  mA

10 mA

100 mA

10 mA

10 mA

100 mA

1  mA

100 mA

10 mA

10 mW

100 mW

1 W

10 W

100 W

1 kW

10 kW

1 mV

1) TRMS measurement
2) Display with (clip-on) current transformers 1000 : 1
3) At 0

0

 ... + 40

0

C

4) With zero adjustment, without zero adju 35 digits

11 MW // <  40 pF
10 MW // <  40 pF
10 MW // <  40 pF
10 MW // <  40 pF

11 MW // <  40 pF

10 MW // <  40 pF

10 MW // <  40 pF

10 MW // <  40 pF

Voltage drop approx.

12 S

13 S

14 S /

15S/16 S

-

-

15 mv

15 mV

15 mv

150 mV

150 mv

150 mv 650 mV

1V

1 V

1V

-

100 mV 100 mV

-

300 mV 270 mV

-

-

150 mV

150 mV

150 mV      -

1 V

1V

1 V

-

300 mV 270 mV

150 mV

-

     -

1V

-

     -

-

-

150 mV

-

-

270 mV

No load voltage

max. 3.2 V

max. 3.2 V

max. 1.25 V

max. 1.25 V

max. 1.25 V

max. 1.25 V
max. 1.25 V

max. 3.2 V

Meas-

urement

Function

Measuring Range

W

A

A ~

 V

 A

> 10 GW // <  40 pF

30.00 mV

10 mV

> 10 GW // <  40 pF

300.0 mV

100 mV

 11 MW // <  40 pF

3.000

V

1 mV

 10 MW // <  40 pF

30.00

V

10 mV

10 MW // <  40 pF

300.0

V

100 mV

10 MW // <  40 pF

1000

V

1 V

3.000

V

1)

1mV

30.00

V

1)

10mV

300.0

V

1)

100 mV

1000

V

1)

1V

 

-

1V

11

circuit current of 25 A by a fuse 1.6 A/500 V in conjuction, with power
diodes. The cut-out capacity of the fuse is 20kA at a rated voltage of
500V

~

 and ohmic load.

The 3 A and 10 A current measuring ranges are protected by a 16A/
600V fuse. The cut-out capacity of the fuse is 100 kA at a normal
voltage of 600 V 

and ohmic load.

Caution:

The measuring ranges 3A and 16 A of ZIEGLER

 

Multi

 13S are not protected

by a fuse!

A blown fuse is signalled on the LCD the instant a measured quantity
having a voltage of more than 4 V is applied to the corresponding
connection sockets. Then, the digital display (9) shows the word
" FUSE"
After a fuse has blown, eliminate the cause of the overload before
using the meter again !
Replacement of the fuses is described in section ’’ 18. Maintenance’’.

9.1AC current measurement with (clip-on) current transformer

9.1.1 T ransformer output mA/A

Caution:

If current transformers are operated with an open circuit on the secondary
side, e.g. due to defective or disconnected leads, a blown fuse in the
meter, or a wrong connection, dangerously high voltages can occur at
the connectors. Therefore, verify that the current circuit of the multimeter
and secondary winding of transformer connected to the multimeter
forman intact circuit. Connect the transformer to the sockets

and mA

and/or A.
The maximum permissible operating voltage is  the nominal voltage of
the current transformer. When reading the measured value, take into
account the transformer ratio and the additional error in indication.

Transf ormer output 

ZIEGLER

Multi

 

12S

The 

ZIEGLER

Multi

 12S shows the switching position ’’

A’’ and the

corresponding sockets. Connect to this socket a (clip-on) current
transformer with a transmission ratio of 1000:1; then the measured values
are displayed directly in the ’’A’’ range.

9.1.2  T ransformer output V

Many transformers have voltage output (refered as mV/A)
The secondary output must therefore be connected to the connection
sockets

and V.

10. Resistance measurement

Verify that the device under test is electrically dead. External voltages
would falsify the measured result!
Set the function selector switch (6) to " W".

Connect the device under test as shown.

Summary of Contents for MULTI 12S

Page 1: ...Printed in India Subject to change without Notice Genius 04 05 2T User Manual ZIEGLER 12S 16S Analog Digital Multimeter Multi ...

Page 2: ...10 A fused 1000 V max 7 10 0 20 30 ON OFF TRMS MAN MAX DATA MIN MAX AUTO MAN F mA 0 C A F W Hz V V V mA 0 C A 8 9 10 11 12 16 15 14 13 18 17 19 VA MIN MAX DC AC ON 8 8 8 8 10 0 20 30 MAN DATA KW MW kHz 0 C mF nF mm 5 19 Servicing When you need service please contact ...

Page 3: ...measurement Rish multi 15S and 16S 14 14 Duty cycle measurement Rish multi 15S and 16S 15 15 Temperature measurement 15 16 Computer interface via RS 232C 16 17 Speci cations 18 18 Maintenance 26 18 1 Battery 26 18 2 Fuses 27 18 3 Case 27 19 Servicing 29 1 Liquid crystal display 2 ON OFF pushbutton 3 Pushbutton for data hold and MIN MAX storage functions 4 Pushbutton for manual range selection 5 Mu...

Page 4: ...R Multi 12S 16S are manufactured and tested in compliance with the safety standard DIN VDE0411 and IEC 1010 1 DIN EN61010 1 VDE0411 1 In case of incorrect use or careless handling the safety of both user and multimeter is not assured For proper use and safe handling it is absolutely necessary to read and understand the operating instructions before using the meter For your safety and for protectio...

Page 5: ...x 0 7 s max 9 s max 2 5 s from 0 to 80 of upper range limit from oo to 50 of upper range limit from 0 to 50 of upper range limit 3 Repair replacement of parts When opening the meter live parts may be exposed Therefore the meter must be disconnected from the measuring circuit prior to opening its case for repair or replacement of parts If repair cannot be avoided unless the meter is opened and live...

Page 6: ...FF Press the ON OFF pushbutton 2 4 Function and range selection The function selector switch 6 is coupled with the Automatic terminal Blocking System ABS which allows access only to two correct sockets for each function Prior to switching to the mA or A functions or from the mA or A functions remove the test lead from the corresponding socket When the test leads are plugged in the terminal blockin...

Page 7: ...section 4 1 4 3 Manual range section You can switch OFF autoranging and select the ranges manually according to the table on the following page Manual mode is switched OFF when pushbutton AUTO MAN is pressed 4 for approximately 1s when the function selector switch 6 is operated or when the meter is turned OFF and ON again When switching back to autoranging from 30 mV or 300 mV ranges 3 V range is ...

Page 8: ...999 is shown by the right triangle 13 6 DATA hold facility The DATA function allows to automatically hold the measured values This is particularly useful for instance when connecting the probes to the measuring point requires full attention When the measured value is applied and the condition according to the table shown below is met the meter holds the measured value on the digital display and em...

Page 9: ...djustment on the 30 mV measuring range Connect the test leads to the meter and join the free ends After having selected the measuring range brie y press the yellow multi function pushbutton 5 The meter acknowledges zero setting by a sound signal the LCD shows 00 00 1 digit and the decimal point ashes The displayed voltage at the instant the pushbutton is pressed is used as reference value max 200 ...

Page 10: ...1 0 29 500 V DC AC eff rms sine 10 min 3 kHz 1200 V 30 kHz 300V 100kHz 30 V 500 V DC AC eff rms sine continu ously 10 min 7 Range 3 V U E 1 5 V eff rms 100 V eff rms 30 V UE 15 V eff rms 300 V eff rms 300V UE 150 V eff rms 1000 V eff rms 8 On the range 3V square wave signal positive on one side 5 15 V f const not 163 84 Hz or integral multiple 9 Without sensor 8 Voltagemeasurement Voltagemeasureme...

Page 11: ...ed alternate switching takes place between DC and AC on the ZIEGLER Multi12S 15S or between DC and DC AC on the ZIEGLER Multi16S The change over is acknowledged by a sound signal The symbols DC and AC 11 are displayed as per selected function on the LCD When selecting a range with the function selector switch 6 the DC function is always set by default When pressing the yellow multi function pushbu...

Page 12: ... 300 Digit Contin uously 0 75 3 10 Digit 1 0 5 10 Digit 1 0 5 10 D 1 0 2 0 25 2 1 0 5 10 Digit 1 0 2 1 0 5 10 Digit 1 0 2 1 5 2 10 Digit 1 5 2 10 Digit 1 5 2 10 Digit 1 5 2 10 Digit 1 5 2 10 Digit 0 36 A 5 0 36 A 5 6 6 6 6 0 36 A 5 0 5 3 4 0 5 3 0 4 1 0 4 1 0 4 1 0 6 1 2 0 1 0 25 1 0 5 5 10 D 0 5 2 0 5 5 10 D 0 5 2 1 0 5 10 D 1 0 2 1 5 4 10 D 1 5 4 10 D 1 75 4 10D 0 4 34 0 4 3 0 2 1 0 2 1 0 2 1 0 ...

Page 13: ...tware MS WINDOWS 3 0 or higher Hardware IBM compatible PC with 1 MB main memory for the WINDOWS version A VGA or EGA monitor A hard disk with 2 MB free storage space A 3 5 disk drive for disks with 1 44 MB storage capacity A MICROSOFT compatible mouse If you wish to make hardcopy a printer supported by WINDOWS ...

Page 14: ...ic load Caution The measuring ranges 3A and 16 A of ZIEGLER Multi13S are not protected by a fuse A blown fuse is signalled on the LCD the instant a measured quantity having a voltage of more than 4 V is applied to the corresponding connection sockets Then the digital display 9 shows the word FUSE After a fuse has blown eliminate the cause of the overload before using the meter again Replacement of...

Page 15: ...unction selector switch 6 15 14 Duty cycle measurement ZIEGLER Multi 15S and 16S With duty cycle measurement we can determine the ratio of pulse duration to cycle time of recurring square wave signals Set the function selector switch 6 to V or V Connections are made in the same way as for voltage measurement See foot note 8 on page 21 Brie y press the yellow multi function pushbutton 5 twice The m...

Page 16: ...Cll format for further processing For the use of ZIEGLER com 100 the following requirements must be met ON 13 Zero adjustment on the 30 Wmeasuring range When measuring small resistance values on the 30 W range you can eliminate the resistance of the leads and contact resistance by zero adjustment Connect the test leads to the multimeter and join the free ends Brie y press the yellow multi function...

Reviews: