Store Emergency Numbers & SMS Numbers
Emergency numbers are the phone numbers that will receive calls from the control
panel when the alarm goes off.
SMS numbers are the phone numbers that will receive alarm SMS from the control panel
when the alarm goes off.
IMPORTANT:
After phone numbers are stored, only those numbers can modify the system
settings. Commands from unauthorized phone numbers will be rejected.
Once an alarm is triggered, the control panel will call the emergency numbers 3 rounds at most, if
a phone is picked up with operation on phone button, the system will stop dialing.
Change RFID Tags Name
You can rename all the RFID tags for your families who carry these tags.
Store SMS Number for RFID Tags
You can assign a phone number that will receive an SMS text notifcation when the
system is disarmed by a RFID tag.
Store Speed Dial Number
After the number is stored, you can dial this number immediately by pressing
[
(f
]
button once on the control panel.
Change Zone Name
10 remote controls and 50 sensors could be extended and the names of sensors are
able to be edited.
This function aims at guiding users to identify the invasion location quickly by changing
the sensor name. Their sequence in naming follows pairing order. For example, the frst
paired sensor is by default setting to zone 1; the second paired sensor is by default
assigned to zone 2, etc. In case of emergency, if you did not change the sensor name,
this control panel will send SMS with zone number to user (e.g. Zone 1 Alarm).
Exit & Entry Delay Time
If you don
’t want to carry remote controls, you can set the exit or entry delay. Suppose
entry delay was set at 30 seconds, the system will allow you 30 seconds to disarm the
system before alarming. Suppose exit delay was set at 35 seconds, the system will allow
you 35 seconds to leave before the system is armed. The
“beep” is heard in every second
to remind you to leave. The pace of reminding sound will speed up in last 15 seconds.
Thus leaves you enough time to leave home without triggering the system.
Single Zone Delay Time
( To apply this function, you should change the zone mode of the sensor to single zone
delay frst. Please refer to
“Zone Mode of Sensor” on page 9).
After the delay time setup, the single zone delay sensor will delay to alarm when it is
triggered.
For example: The exit & delay time is set at 30 seconds; single zone delay time is set at
40 seconds.
Sensor
Arm
Alarm
Normal and home mode zone
Delay 30s to arm
Delay 30s to alarm
Single zone delay zone
Delay 30s to arm
Delay 40s to alarm
24-H zone
Always in arm state
Alarm immediately
Disarm Password
The default disarm password is 1234. It is suggested to change the passcode for
safety.
13